HP XP P9500 Manual page 232

Hp p9000 remote web console messages (av400-96401, october 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 58 Error codes (part code 6510) (continued)
Part
Error
Code
Number
6510
59328
6510
59329
6510
59330
6510
59331
6510
59335
6510
65664
6510
65665
6510
65777
6510
65778
6510
65779
6510
65780
6510
69016
6510
69017
232 Message (part code group 6nnn)
Error Message
Check the status of the specified master
journal.
The journal volume cannot be deleted,
because the attribute of mirror for the
journal is "master" and the status of the
mirror is "Hold" or "Holding."
The serial number of the local DKC is
entered. Select the check box when you
add the journal of the local DKC to the
extended consistency group (EXCTG).
The local DKC cannot be specified for
the extended consistency group (EXCTG),
because the serial number other than the
local DKC is entered.
Delete the entered DKC to use the journal
of the local DKC.
A LUSE volume is included in the
specified volumes.
The current version of the microcode
does not allow you to create pairs using
LUSE volumes.
The value of the path watch time is not
entered or is outside the range. Check
the value of the path watch time.
The specified volume is not valid for this
program product. Specify another
volume.
The specified volume is not the volume
to be monitored. Check the monitoring
setting.
The current microcode version of
DKCMAIN cannot assign remote
command devices to mirrors.
No more remote command devices can
be assigned to the specified mirror.
There are no mirrors available to assign
a remote command device.
The same mirror ID is specified in the
mirror 1 and the mirror 2 parameters.
Are you sure you want to cancel the
export?
No more journals can be registered,
because the number of registered
journals has reached the maximum.
Recommended Action
Change the status of mirror of the journal
to "Initial," then retry the operation.
Click the check box when you add the
journal of the local DKC to the extended
consistency group (EXCTG).
Delete the entered DKC to use the journal
of the local DKC.
Check whether the specified volume is
a LUSE volume. Also, check storage
system's microcode version.
Check the value of the path watch time.
Specify another volume.
Check the monitoring setting.
The microcode versions between the
DKCMAIN and the SVP might not match.
Confirm the microcode versions of the
DKCMAIN and the SVP.
Check if a remote command device was
assigned to the specified mirror.
Check if the specified journals include
mirrors available to assign a remote
command device.
Specify different mirror IDs in the mirror
1 and the mirror 2 parameters.
To stop the operation, click [OK].
To continue the operation, click [Cancel].
Check the number of registered journals.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
i
W