Table 55 Error codes (part code 6010) (continued)
Part
Error
Code
Number
6010
65773
6010
65774
6010
65804
6010
69018
6010
69022
6010
69023
6010
69033
6010
69034
6010
69035
6010
69036
6010
69037
6010
69038
6010
69039
6010
69071
186 Message (part code group 6nnn)
Error Message
The serial number and the controller ID
of the RCU registered in a quorum disk
do not correspond with the specified
RCU.
The serial number and the controller ID
of the RCU registered in a quorum disk
do not correspond with the information
of RCU used by the specified pair.
The quorum disk ID was not specified.
When the [Change attribute to ESAM]
parameter has been changed from [No]
to [Yes], specify the quorum disk ID.
There are two or more LDKC numbers
for the specified data volume. In this
operation, please specify only one LDKC
number.
There are no RCUs available. Register
RCUs in the CU or RCUs of CU Free,
then retry the operation.
There are no RUCs available.
Since the number of preview data
exceeded the maximum, the excess data
were discarded. No more preview data
can be stored.
The number of preview data exceeds the
maximum.
No more preview data can be stored.
Different CU numbers coexist in the
selected M-VOLs. Select M-VOLs so that
different CU numbers do not coexist in
the M-VOLs, and retry the operation.
The file name should be from 1 to 32
characters.
More than 256 script files cannot be
transferred to the SVP.
File name is not selected.
Are you sure you want to delete the
selected file?
The current DKCMAIN microcode cannot
use External Storage Access Manager.
Recommended Action
Select a RCU and a quorum disk ID that
have the same serial number and the
controller ID, then retry the operation.
Select the quorum disk ID corresponding
with the serial number and the controller
ID of the RCU that which is used by the
specified pair, then retry the operation.
Specify the quorum disk ID, then retry
the operation.
Check the LDKC number for the specified
data volume, and specify only one LDKC
number.
Register RCUs in the CU or RCUs of CU
Free, then retry the operation.
To create pairs where different CU
numbers exist, register RCU of CU Free
and retry the operation.
To crate pairs with RCU in the CU, select
the M-VOLs again so that different CU
numbers do not coexist in the M-VOLs,
and then retry the operation.
Click [OK]. Apply the Preview data to
the disk storage system, then retry the
operation.
Click [OK]. Apply the Preview data to
the disk storage system, then retry the
operation.
Select M-VOLs so that different CU
numbers do not coexist in the M-VOLs,
and retry the operation.
Change the number of characters used
for the file name to less than 32, then
retry operation.
Delete the unnecessary script files, then
retry the operation.
Select the file name, then retry the
operation.
To delete the file, click [OK], To cancel
the deletion, click [Cancel].
Please contact HP Technical Support after
checking the version of the DKAMAIN
microcode.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W