Table 22 Error codes (part code 0605) (continued)
Part
Error
Error Message
Code
Number
Systems or the Disconnect External
Volume is in progress.
0605
58410
The cache mode cannot be changed
because the bind mode is set to the
specified volume.
0605
5841 1
Set the same cache mode to all the
volumes that compose a LUSE volume.
0605
58622
The configuration of Pool VOL is defined.
0605
58623
The specified operation cannot be done,
because the Snapshot pair using the Pool
VOLs to be maintained is in PSUS status
or being restored.
0605
58626
A Snapshot pair is defined.
0605
58710
The specified volumes include remote
command devices registered in the
extended consistency group of
Continuous Access Journal Z.
0605
58905
The extended shared memory for
External Storage is not installed.
0605
65740
The configuration changing processes
are conflicting at DKC.
0605
65791
The specified External Path Group is not
mounted.
0605
65792
The specified External Path Group has
already been mounted.
0605
65793
The specified External Path Group has
already been used.
0605
65794
The specified external volume is not
mounted.
0605
65795
The specified external volume has
already been specified.
0605
65796
The External Path Group specified as a
migration source has already been used
as a migration target.
0605
65797
The External Path Group specified as a
migration target has already been used
as a migration source.
0605
65798
The path configuration of the External
Path Group between the migration
source and the migration target is
different.
Recommended Action
Volumes, put the external volume in
normal status, then retry the operation.
Release the bind mode setting, then retry
the operation.
If there is a volume whose cache mode
cannot be changed due to its bind mode
setting, release the bind mode setting
first.
Release the configuration definition of
Pool VOL, then retry the operation.
Resynchronize or release the definition
of Snapshot pair, then retry the
operation.
Cancel the pair definition, then retry the
operation.
Delete all the Journal registered in the
extended consistency group, then retry
the operation.
The extended shared memory for
External Storage needs to be installed.
Please contact HP Technical Support.
Check if the configuration changing
process by RAID Manager, Auto LUN,
or Quick Restore is not in the operation,
then retry the operation.
Check the specified External Path Group.
Check the specified External Path Group.
Clear the duplicated setting, then retry
the operation.
Check the specified external volume.
Exclude the duplicated setting, then retry
the operation.
Clear the duplicated setting, then retry
the operation.
Clear the duplicated setting, then retry
the operation.
Check the specified External Path Group.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Part code 0605