HP XP P9500 Manual page 176

Hp p9000 remote web console messages (av400-96401, october 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 53 Error codes (part code 6005) (continued)
Part
Error
Code
Number
6005
68827
6005
68829
6005
68830
6005
68831
6005
68844
6005
68845
6005
68846
6005
68847
176
Message (part code group 6nnn)
Error Message
The operation failed, because there was
an error in the specified parameter.
The specified volume has already been
set to the quorum disk.
The specified volume is not a quorum
disk.
The operation failed, because the
specified quorum disk was used for
External Storage Access Manager.
The operation failed, because the
specified M-VOL was a volume of Thin
Provisioning or Thin Provisioning Z
volume whose zero data was being
discarded.
The operation failed, because the
specified R-VOL was a volume of Thin
Provisioning or Thin Provisioning Z
volume whose zero data was being
discarded.
The operation failed, because the pool
associated with the Thin Provisioning
volume or Thin Provisioning Z volume
that is specified as the M-VOL was
being initialized.
The operation failed, because the pool
associated with the Thin Provisioning
volume or Thin Provisioning Z volume
Recommended Action
The serial number of the
local DKC cannot be set
as the serial number of
the other DKC. Check the
input serial number of the
other DKC.
A quorum disk cannot be
registered in a same
external storage device
with a different quorum
disk ID. Check whether a
quorum disk is registered
in the selected external
storage device with a
different quorum disk ID.
The serial number of the
other DKC, which is set
from MCU (or RCU)
when registering a
quorum disk, might be
different from the serial
number of the RCU (or
MCU). Check the input
serial number of the other
DKC, which is set from
MCU (or RCU) when
registering a quorum
disk.
Check the volume setting.
Check the volume setting.
Release all the pairs of
External Storage Access
Manager of the specified
quorum disk ID, then retry
the operation.
Retry the operation after the
completion of discarding
zero data on the specified
volume.
Retry the operation after the
completion of discarding
zero data on the specified
volume.
Wait until the initialization
of the pool is completed,
and then retry the operation.
Wait until the initialization
of the pool is completed,
and then retry the operation.
Severity Level
W
W
W
W
W
W
W
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000P9500

Table of Contents