Table 59 Error codes (part code 6610) (continued)
Part
Error
Error Message
Code
Number
6610
59151
The current microcode version of
DKCMAIN only supports OPEN-V as the
emulation type of a journal volume.
6610
59152
There are two or more kinds of emulation
types that cannot be combined, in the
specified volume. Or you tried to add a
volume which cannot be combined with
the emulation type of the existing volume.
6610
59153
The journal volume cannot be deleted,
because the mirror status of the journal
is Active.
6610
59321
No more journal can be added to the
specified extended consistency group
(EXCTG).
6610
59322
There are no valid extended consistency
groups (EXCTG).
6610
59323
The entered parameter is invalid. The
serial number, the LDKC number, or the
journal to be added is not specified.
6610
59324
Some of the specified journals belong to
an extended consistency group (EXCTG).
The timer type for journals which belong
to EXCTG must be "System."
6610
59325
A pair which is ready for Delta resync
cannot be created under the current
status of the specified master journal.
Check the status of the specified master
journal.
6610
59326
Specify a mirror ID other than "0" if you
create a pair ready for Delta resync.
6610
59327
You cannot specify [Entire] or [None] to
the Initial copy mode under the current
status of the specified master journal.
Check the status of the specified master
journal.
6610
59328
The journal volume cannot be deleted,
because the attribute of mirror for the
journal is "master" and the status of the
mirror is "Hold" or "Holding."
6610
59329
The serial number of the local DKC is
entered. Select the check box when you
add the journal of the local DKC to the
extended consistency group (EXCTG).
6610
59330
The local DKC cannot be specified for
the extended consistency group (EXCTG),
because the serial number other than the
local DKC is entered.
Delete the entered DKC to use the journal
of the local DKC.
Recommended Action
To use a mainframe volume as a journal
volume, please contact HP Technical
Support to update the microcode version
of DKCMAIN.
Check the emulation type of the specified
volume.
Change the mirror status of the journal
to Stop or Initial, then retry the operation.
Check the number of journals in the
specified extended consistency group
(EXCTG).
Check whether all extended consistency
groups (EXCTG) are used by other
program products.
Check the entered parameter.
Check if the specified journals include
the journals which belong to an extended
consistency group (EXCTG).
Check the status of the specified master
journal.
Specify a mirror ID other than 0.
Check the status of the specified master
journal.
Change the status of mirror of the journal
to "Initial," then retry the operation.
Click the check box when you add the
journal of the local DKC to the extended
consistency group (EXCTG).
Delete the entered DKC to use the journal
of the local DKC.
Severity