Table 33 Error codes (part code 3005) (continued)
Part
Error
Code
Number
3005
7060
3005
71 1 1
3005
7310
3005
8000
3005
8001
3005
8002
3005
8100
3005
8102
3005
8971
3005
8979
3005
55505
3005
55506
3005
55507
3005
55508
3005
55509
3005
55510
3005
5551 1
3005
55512
3005
55513
3005
55514
88
Message (part code group 3nnn)
Error Message
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
A communication time-out error
occurred in the disk subsystem.
An error occurred during SVP
processing.
An error occurred while connecting to
the subsystem.
This function is not supported.
An error occurred while communicating
with the storage system.
The operation of the external volume
has been failed because all the paths
to the external volume are blocked.
The specified operation cannot be
performed, because the Pool-VOL in the
same Pool has been specified to
migrate to a different CLPR.
Pool ID=%s
The specified volume is used as a
reserved volume of Auto LUN.
The specified volume is used as a
command device.
The specified volume has Volume
Security for Mainframe setting.
The specified volume is used as a LUSE
volume.
An error occurred during SVP
processing.
The emulation type of the specified
volume is not OPEN-V.
The specified volume is an external
volume.
The specified volume is used as a
V-VOL.
The specified volume is not configured.
Recommended Action
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Check whether the DKCMAIN microcode
version and the SVP microcode version
are mismatched.
The configuration may be inconsistent.
Click [Refresh All] on the [File] menu and
refresh the configuration.
Restore more than one path to the
external volume, and then perform the
operation of the external volume.
Check the setting.
Release the reserved volume setting or
specify another volume.
Release the command device setting or
specify another volume.
Release the Volume Security for
Mainframe setting or specify another
volume.
Release the LUSE volume setting or
specify another volume.
If this problem persists, please contact
HP Technical Support.
Specify another volume.
Specify another volume.
Specify another volume.
Specify another volume.
Severity
Level
E
E
E
E
E
E
E
E
W
W
W
W
W
W
W
E
W
W
W
W