Table 22 Error codes (part code 0605) (continued)
Part
Error
Code
Number
0605
65799
0605
65800
0605
65801
0605
65802
0605
6601 1
0605
66012
0605
66013
0605
66014
0605
66501
0605
66502
0605
66503
0605
66504
0605
66505
0605
66506
0605
66507
0605
66508
0605
66509
0605
66510
0605
66512
0605
66517
0605
66518
52
Message (part code group 0nnn)
Error Message
There are no setting lines of
NewPathGroup.
The number of NewPathGroup setting
lines exceeds the limit.
There are no setting lines of the ExG.
There are no setting lines of
TargetPathGroup.
The number of external LUs that can be
connected from a single port has
exceeded the maximum value.
The number of registered ports of the
external storage system has exceeded
the maximum.
The specified emulation type cannot be
set because 3390-3R is set in the storage
system.
The specified emulation type cannot be
set because 3390-3 is set in the storage
system.
The number of LDEVs that can be defined
in an external volume has exceeded the
maximum value.
Specified ExG has already been used.
LDKC, CU, and LDEV are not set within
the range where they can be used.
Specified LDKC:CU:LDEV has already
been used.
The specified LDEV number has already
been assigned to another emulation
group within the range grouped by 32
LDEV numbers.
Specified SSID has already been used.
The target external volume is blocked or
not set within the range of capacity that
can be used.
The specified LDEV capacity is invalid.
The total LDEV capacity defined in the
external volume exceeds the external
volume size.
The specified emulation type cannot be
used.
Specified CLPR is not mounted.
The target external volume has already
been mapped or set for mapping.
The External Path configuration of the
target external volume is not
Recommended Action
Check the contents of the spreadsheet.
Check the contents of the spreadsheet.
Check the setting of ExG.
Check the contents of the spreadsheet.
Delete unnecessary external LU(s), then
retry the operation.
Operate within the ports of the
connected external storage system.
Change the emulation type to be set in
the volume.
Change the emulation type to be set in
the volume.
Check the number of LDEVs.
Check the setting of ExG.
Check the setting of LDKC, CU, and
LDEV.
Check the setting of LDKC, CU, and
LDEV.
Check the setting of emulation groups
within the range grouped by 32 LDEV
numbers.
Check the setting of SSID.
Check the status and the capacity of
target external volume.
Check the setting of LDEV capacity.
Check the setting of LDEV capacity.
Check the setting of emulation type.
Check the setting of CLPR.
Check the configuration and the setting
of external volume.
Check the setting of path configuration.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W