Hp storageworks p9000 virtualization adapter release notes (5697-0681, october 2010) (4 pages)
Summary of Contents for HP XP P9500
Page 1
P9000 for Business Continuity Manager Software Messages Abstract This guide describes the error messages and error codes that are produced by HP Business Continuity Manager Software including: HP Business Continuity Manager, HP Business Continuity Manager Basic, HP Business Continuity Manager Extended CT Group, and HP Business Continuity Manager Universal Replicator 4x4 Extended CTG.
Page 3
Edition Date Description Tenth September 201 1 This document revision applies to Business Continuity Manager version 6.61 and higher. Eleventh November 201 1 This document revision applies to Business Continuity Manager version 6.70 and higher. Twelfth April 2012 This document revision applies to Business Continuity Manager version 6.71 and higher.
Contents 1 Messages....................5 Message Format........................5 Message Output Format......................5 Notations Used to Describe Messages..................6 Message Output Destination......................7 List of Messages........................7 Multi-line Messages Output to SYSTSPRT..................159 YK8310I PRT........................159 YK8312I PRT........................160 YK8314I PRT........................160 YK8316I PRT........................161 YK8318I PRT........................161 YK841 1I PRT........................162 YK8413I PRT........................162 User Completion Codes......................163 Identifying the Volume to Be Processed..................163 Identifying the Volume Serial Number from the REXX Script............163 Identifying the Volume Serial Number from the Configuration File...........164...
1 Messages This chapter describes the messages that are issued by Business Continuity Manager: “Message Format” (page 5) “Message Output Destination” (page 7) “List of Messages” (page 7) “Multi-line Messages Output to SYSTSPRT” (page 159) “User Completion Codes” (page 163) “Identifying the Volume to Be Processed”...
Message Output Destination The following destinations appear in messages issued by Business Continuity Manager: MSG: Message structure TSO: TSO/E terminal CON: Console SYS: SYSLOG PRT: SYSPRINT or SYSTSPRT LOG: ISPF log ISPF: ISPF panel XML: HP P9000 Command View Advanced Edition Software log and window If MSGID ON is specified using the ISPF system command, the message ID and message text are displayed in the ISPF panel.
Page 8
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8008E CON BCM Monitor initialization An attempt to start BCM Monitor failed because of the reason failed: termination-code. indicated in a preceding message that was output to either the console or dd SYSTSPRT.
Page 9
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8017E CON Invalid command: There is an error in the command-name command. command-name. Make sure that the entered command is valid. YK8018E CON Operand is incorrect: There is an error in an operand of the command-name command.
Page 10
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions return-code 20: EXEC processing failed. 20021: There was an error in the parameter list that was passed to IRXJCL.
Page 11
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8028E CON BCM Monitor function The main task or subtask terminated abnormally during BCM abend: code=Sxxx Uxxxx Monitor processing.
Page 12
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions This is only displayed when the output destination is SYSTSPRT. label Label at which BCM Monitor stops YK8041I PRT CON time BCM Monitor will stop BCM Monitor will stop at the end of a cycle.
Page 13
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions time Message output time This is only displayed when the output destination is SYSTSPRT. YK8047I PRT CON time Set MONITOR=-status BCM Monitor set the monitoring status of the copy group cgid to for Copy Group 'cgid'.
Page 14
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8055I PRT CON time BCM Monitor will BCM Monitor will go to sleep because the PAUSE action was pause now for ‘sleep-time’...
Page 15
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions This is only displayed when the output destination is SYSTSPRT. nnn (decimal number) Return code of the FREEMAIN macro YK8075E PRT time Parameter syntax error There is a syntax error in a parameter.
Page 16
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions param-name Name of the required parameter YK8079E PRT time CGID parameter must Specify the CGID parameter at the beginning of the copy group be specified first : rec#.
Page 17
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions Copy group ID specified in the ACTION parameter YK8084E PRT time The continuation symbol The continuation symbol was specified for the final record. can not be specified in the time final record : file.
Page 18
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions The number of lines equal to the number of messages included in the message structure are displayed. YK8221I PRT CON time YKEWAIT (RC=4) : The YKEWAIT command timed out before the transition to the...
Page 19
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions This is only displayed when the output destination is SYSTSPRT. YK8301I PRT CON time Not all volumes are in The action identified by action will be executed because there is a 'status'.
Page 20
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions GROUP STATUS : status prefix MATCHING% : match Prefix REVERSED% : rev% ATTIME(GMT) : attime- simplexct STATUS : attms Number of copy pairs in SIMPLEX status pendingct Number of copy pairs in PENDING status...
Page 21
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions Copy direction >: Primary-to-secondary <: Secondary-to-primary sdevn Secondary device number status Copy pair status match Copy pair matching percentage ctid Consistency group ID or master journal group sub-ctid...
Page 22
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8317I CON REPORT STATS: This message indicates the results of REPORT(STATS) for the TCA copy group. COPY GROUP : cgid TYPE : cgtype cgid DAD-ID : dad PREFIX : prefix...
Page 23
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8318I “YK8318I PRT” (page 161). YK8319I CON REPORT STATS: This message indicates the results of REPORT(STATS) for the Cnt Ac-J Z copy group.
Page 24
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8321I PRT CON time Some volumes are in a Some volumes are in the TRANSITION status. 'TRANSITION' status. time Message output time This is only displayed when the output...
Page 25
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8401I PRT CON time Check Startup Status of BCM Monitor will start checking the status of the copy group Copy Group 'cgid'.
Page 26
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK8410I PRT CON time ---- date ---- The date is displayed when BCM Monitor is started or when the date changes while BCM Monitor is running.
Page 27
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions Route label cgmonstat Copy group monitoring status (ACTIVE or INACTIVE) cgsastat Copy group startup status to be checked when BCM Monitor starts cgsaact Startup action executed if the copy pair status...
Page 28
Table 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YK80x) (continued) Message ID Message Text Explanation and Recommended Actions YK9080E CON The expiration date for your The license (function) has expired. license key (function). To continue using this product after the expiry date, you need a permanent license.
Page 29
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions Type of system error YKA007E TSO TIMEOUT() value not valid The value specified in the TIMEOUT parameter is invalid. YKA008E TSO TIMEOUT() parameter If GET or CLOSE is specified in the OP parameter, you cannot...
Page 30
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions 8: An I/O error occurred in a volume within the search range. The copy group definition file was created for the volume that was successfully detected.
Page 31
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions on the length of the error messages, they might extend over several lines. YKB200W TSO No information was No copy pair information was acquired from the volume to which acquired for the device number was assigned.
Page 32
Table 2 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKA0x) (continued) Message ID Message Text Explanation and Recommended Actions CCA# The command control address number of the detected undefined volume YKB204W TSO A dynamic configuration A dynamic change was detected in an I/O configuration definition change was detected.
Page 33
Table 3 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKC0x) (continued) Message ID Message Text Explanation and Recommended Actions stem Stem name assigned to the MSG parameter YKC002E MSG Results STEM(stem) does not The last character of the STEM parameter is not a period. SC=48 RC=48 include trailing "."...
Page 34
Table 3 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKC0x) (continued) Message ID Message Text Explanation and Recommended Actions Check the disk configuration definition file after the scan is complete. If the volume serial number is different from the one in the actual configuration, re-execute the scan.
Page 35
Table 4 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKD0x) (continued) Message ID Message Text Explanation and Recommended Actions YKD058E MSG Some pairs in this group do One or more devices in the HP XP 256 Disk Array storage system SC=36 RC=48 not support Hitachi do not support TCA copy groups.
Page 36
Table 5 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKE0x) (continued) Message ID Message Text Explanation and Recommended Actions Stem name assigned to the MSG parameter YKE002E MSG TIMEOUT() value invalid The value assigned to the TIMEOUT parameter is invalid. SC=48 RC=48 YKE003E MSG GOTO value is invalid.
Page 37
Table 6 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKF0x) (continued) Message ID Message Text Explanation and Recommended Actions YKF001E MSG No results STEM() supplied Nothing is assigned to the STEM parameter. SC=48 RC=48 YKF002E MSG Copy Group STEM(stem) The last character of the STEM parameter is not a period.
Page 38
Table 7 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG0x) (continued) Message ID Message Text Explanation and Recommended Actions YKG003E TSO Unable to update MSG(stem) An attempt to assign a value to a Message structure variable failed. RC=52 in Caller's environment.
Page 39
Table 7 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG0x) (continued) Message ID Message Text Explanation and Recommended Actions rec# Number of the line in the file identified by file where the error was detected YKG052W MSG Expecting new element.
Page 40
Table 7 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG0x) (continued) Message ID Message Text Explanation and Recommended Actions Name of the XML file where the error was detected rec# Number of the line in the file identified by file where the error was detected YKG075W MSG Unrecognized Encoding...
Page 41
Table 7 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG0x) (continued) Message ID Message Text Explanation and Recommended Actions v.r.m API level For details about this value, see the information about the XML document type definitions in the HP P9000 for Business Continuity Manager Software Reference Guide.
Page 42
Table 7 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG0x) (continued) Message ID Message Text Explanation and Recommended Actions YKG092E MSG File Read error: dsstate. An attempt to read the XML file identified by file failed. SC=40 RC=40 dsstate (file)
Page 43
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions file Name of the XML file where the error was detected rec# Number of the line in the file identified by file where the error was detected YKG251E MSG name attribute missing.
Page 44
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKG271E MSG The element name is The required XML element name is missing. SC=36 RC=36 required, but no element Correct the specification on the line with the line number identified (file:rec#) was found.
Page 45
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions Number of the line in the file identified by file where the error was detected YKG277E MSG name element missing.
Page 46
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKG298E MSG YKGETHDA encountered an An unexpected error has occurred. TSO SC=44 RC=44 unexpected error. This error might have occurred with another error. (detailed-info) If another error message was output at the same time as this one, follow the instructions in that message to fix the corresponding...
Page 47
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKH002I TSO No copy pair was No copy pairs were detected within the specified range. discovered. Check the operating range and status of the copy pair that you want to acquire, and execute the YKH2B command again.
Page 48
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKH201W TSO No I/O paths are available No copy pair information was acquired from the volume to which for the specified devices.
Page 49
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKH205W TSO This copygroup does not Cnt Ac-S Z with the HyperSwap attribute cannot be used in this support LinkageOption=HS.
Page 50
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions If no additional information is available, a space is displayed. The error messages message-text, message-value, and message-severity are displayed in the TSO/E terminal. Depending on the length of the error messages, they might extend over several lines.
Page 51
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions DD name of the CSV file where the error was detected YKJ152E TSO Failed to operate csv file: The CSV file operation will stop because an error occurred when RC=40 dd-name: dsstate...
Page 52
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKJ202I TSO RC=4 No copy pair is defined in No copy pair is defined in the pair information CSV file. No data specified Pair information was written in the copy group definition file.
Page 53
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions rec# Number of the line in the file identified by dd-name where the error was detected YKJ208W TSO Inconsistencies exist among The S-VOL specified with the device number differs from the S-VOL RC=8...
Page 54
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions YKJ212E TSO A specific combination of a The combination of the copy groups is one of the following: RC=32 storage system serial number The serial numbers of the primary site storage systems are the same;...
Page 55
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions Number of the line in the file indicated by dd-name where the error was detected. YKJ250E TSO name is not specified in No value is assigned to the item identified by name in the EXCTG RC=32...
Page 56
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions Number of the line in the file identified by dd-name where the error was detected If the EXCTG information CSV file does not include a line that specifies the supervisor DKC, nothing is displayed for rec#.
Page 57
Table 8 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKG2x) (continued) Message ID Message Text Explanation and Recommended Actions execution-date Time at which the YKINSCHK command was executed The time is indicated in the format YYYY/MM/DD YY:MM:SS YKK101E TSO Failed to get security setting Security setting information could not be acquired.
Page 58
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text Explanation and Recommended Actions YKL005E MSG STEM(stem) does not include The last character of the STEM parameter is not a period. SC=48 RC=48 trailing "."...
Page 59
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text Explanation and Recommended Actions type definitions, in the HP P9000 for Business Continuity Manager Software Reference Guide. file Name of the XML file where the error was detected rec# Number of the line in the file identified by file...
Page 60
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text Explanation and Recommended Actions rec# Number of the line in the file identified by file where the error was detected YKL077W MSG APIInfo Level=level invalid.
Page 61
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text Explanation and Recommended Actions YKL082W MSG Unable to resolve secondary The YKLOAD program failed to resolve the unit number (device SC=8 RC=8 device address.
Page 62
Table 9 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL0x) (continued) Message ID Message Text Explanation and Recommended Actions YKL090E MSG File Allocation Failed: dsstate. An attempt to allocate the XML file identified by file failed. Verify SC=40 RC=40 (file) that the XML file identified by file is correctly created.
Page 63
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions YKL205E MSG name parameter is too long. The parameter identified by name is too long. SC=48 RC=48 YKL206E MSG Route parameter is allowed The ROUTE parameter is allowed on the first call of the YKLOAD...
Page 64
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions Correct the specification on the line with the line number identified by rec# in the file identified by file. file Name of the XML file where the error was detected...
Page 65
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions YKL274E MSG ETag name is mismatch. The specified ETag name /incorrect-ETag-name is not the expected SC=36 RC=36 /correct-ETag-name is ETag name /correct-ETag-name.
Page 66
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions YKL281E MSG No command devices are No command device was found that is defined in the route for SC=36 RC=36 defined for routes that issue remote command issuance or with the specified route label.
Page 67
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions If function-name is Cnt Ac-S Z Sync Extended CTG: No C/T group ID can be specified for the Hitachi TrueCopy™ for Mainframe (Cnt Ac-S Z) copy group because the license key required for the function for preserving consistency has not been installed.
Page 68
Table 10 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKL2x) (continued) Message ID Message Text Explanation and Recommended Actions If no other error message was output, collect the following materials and contact service representative: The script from which this command was executed (not necessary if this command was executed from the ISPF panel).
Page 69
Table 1 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM0x) (continued) Message ID Message Text Explanation and Recommended Actions YKM008E MSG DEVN() not valid hex The value specified in the DEVN parameter is not in hexadecimal SC=48 format.
Page 70
Table 1 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM0x) (continued) Message ID Message Text Explanation and Recommended Actions YKM023E ISPF Invalid value The value is invalid. YKM024E ISPF Choose any one Choose one. YKM025E ISPF C/T ID cannot be added to a You cannot add a copy group to a copy group container if no CopyGroup Container...
Page 71
Table 1 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM0x) (continued) Message ID Message Text Explanation and Recommended Actions Z/CA/TCA Copy Group definition. YKM042E ISPF This Consistency Group ID This C/T group ID is already defined. Choose a different ID. (C/T ID,sub C/T ID) is already defined.
Page 72
Table 1 1 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM0x) (continued) Message ID Message Text Explanation and Recommended Actions Check that the command can be executed on this copy group, and then re-execute the command. YKM099I TSO YKMAKE command return The YKMAKE command terminated with the return code nnnn and...
Page 73
Table 12 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM1x – YKM5x) (continued) Message ID Message Text Explanation and Recommended Actions connections that is allowed within the same CU. YKM508E ISPF This inter-CU path is already This inter-CU path is already defined in another logical path.
Page 74
Table 12 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM1x – YKM5x) (continued) Message ID Message Text Explanation and Recommended Actions remdad The device address domain ID you specified YKM521E ISPF You cannot exit this panel until The exit operation cannot be performed until you define a you define a command device.
Page 75
Table 13 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM7x) (continued) Message ID Message Text Explanation and Recommended Actions loclen Input length YKM707E ISPF Enter the number (hex. Enter the hexadecimal characters (0-9, A-F, a-f) that you want characters: 0-9, A-F, a-f) to to search for.
Page 76
Table 13 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM7x) (continued) Message ID Message Text Explanation and Recommended Actions Maintenance information YKM750E ISPF Serial number must be a 5-digit Serial numbers must be a 5-digit combination of alphanumeric combination of alphanumeric characters.
Page 77
Table 13 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM7x) (continued) Message ID Message Text Explanation and Recommended Actions YKM759E ISPF Enter numeric characters (0-9). Enter a numeric value (0-9). YKM760E ISPF Preset Mode cannot be used You cannot set the Preset Mode without specifying a C/T group when C/T ID is not specified.
Page 78
Table 13 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM7x) (continued) Message ID Message Text Explanation and Recommended Actions YKM775E ISPF Panel could not proceed the The storage system cannot be added because the number of insert action because number storage systems defined in the route is already at the maximum.
Page 79
Table 14 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKM9x) (continued) Message ID Message Text Explanation and Recommended Actions YKM905E TSO A GETMAIN error occurred. A GETMAIN error occurred. The program will stop running. Contact technical support for assistance. YKM906E TSO A FREEMAIN error occurred.
Page 80
Table 16 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKP0x) Message ID Message Text Explanation and Recommended Actions YKP000T TSO RC=48 Supplied parameters invalid Invalid parameters are specified. For details, see the reason code in the YKP099I message that will appear after this message.
Page 81
Table 17 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKQ0x) Message ID Message Text Explanation and Recommended Actions YKQ000T TSO RC=48 Supplied parameters invalid Invalid parameters are specified. For details, see the reason code in the YKQ099I message that will appear after this message.
Page 82
Table 17 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKQ0x) (continued) Message ID Message Text Explanation and Recommended Actions CCA# Command control address number If the device cannot be identified, ** is displayed. pair-index See the pair index description in the explanation of the YKE003E message.
Page 83
Table 17 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKQ0x) (continued) Message ID Message Text Explanation and Recommended Actions CCA# Command control address number If the device cannot be identified, ** is displayed. pair-index See the pair index description in the explanation of the YKE003E message.
Page 84
Table 18 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKR0x) (continued) Message ID Message Text Explanation and Recommended Actions For details, see the reason code in the YKR099I message that will appear after this message. For reason codes, see IKJPARS in the TSO/E Programming Services.
Page 85
Table 19 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKS0x) Message ID Message Text Explanation and Recommended Actions YKS001E TSO RC=48 Unable to execute without valid Specify a valid MSG parameter. MSG() parameter. YKS002E TSO RC=48 MSG(stem) does not include The last character of the MSG parameter is not a period.
Page 86
Table 19 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKS0x) (continued) Message ID Message Text Explanation and Recommended Actions configuration file, and then create a new configuration file that has correct file attributes. RECFM = XX.RECFM must be YY The file is unavailable because the RECFM attribute value is abnormal.
Page 87
Table 20 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKS2x) Message ID Message Text Explanation and Recommended Actions YKS203E TSO RC=52 Invoke YKSTORE REXX Script via The YKSTORE REXX program can only be invoked via the YKSTORE Assembler subroutine.
Page 88
Table 20 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKS2x) (continued) Message ID Message Text Explanation and Recommended Actions file. Change the dataset format of the configuration file into PS. CANNOT GET DSSTATE, reason code=nnnn The dataset information cannot be obtained, or the configuration file is not assigned.
Page 89
Table 21 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKT0x) (continued) Message ID Message Text Explanation and Recommended Actions YKT003E CON No SVC #'s available No SVC number available. The program abnormally terminates with user completion code 996. YKT004E CON Couldn't add SVC entry SVC number addition failed in the SVCUPDTE macro.
Page 90
Table 22 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKT2x) Message ID Message Text Explanation and Recommended Actions YKT210E CON RC=8 System task started without START The command was invoked from the TSO/E from TSO. environment. The program stops processing. Invoke the command using the START command, or as a batch JOB.
Page 91
Table 22 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKT2x) (continued) Message ID Message Text Explanation and Recommended Actions A maximum of 8 characters can be specified. Specify a correct value, and then retry the operation. YKT232E CON RC=12 The task is not APF-authorized.
Page 92
Table 23 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKT4x) (continued) Message ID Message Text Explanation and Recommended Actions If no value has been set for the Business Continuity Manager environment variable by using the YKSETENV command, N/A is displayed.
Page 93
Table 24 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKU0x) (continued) Message ID Message Text Explanation and Recommended Actions Time value assigned to the ATTIME parameter YKU003E MSG SC=48 SVOL(PROTECT|PERMIT) option Either PROTECT or PERMIT must be specified for the RC=48 required SVOL parameter.
Page 94
Table 24 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKU0x) (continued) Message ID Message Text Explanation and Recommended Actions parameter specified. These parameters are invalid on Cnt Ac-J Z copy groups. Re-execute the YKSUSPND command without specifying the ATTIME or CANCEL parameter.
Page 95
Table 25 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKV0x) (continued) Message ID Message Text Explanation and Recommended Actions YKV050E MSG SC=36 Invalid Copy Group attribute The specified copy group attribute value is invalid for RC=48 (attribute-value) name this command.
Page 96
Table 26 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKW0x) (continued) Message ID Message Text Explanation and Recommended Actions P9000 for Business Continuity Manager Software Reference Guide. YKW007E TSO YKQUERY error return code = The YKWATCH command uses the YKQUERY command nnnn.
Page 97
Table 27 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKX0x) Message ID Message Text Explanation and Recommended Actions YKX000T TSO Supplied parameters invalid Invalid parameters are specified. For details, see the reason code in the YKX099I message that will appear after this message.
Page 98
Table 28 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKX1x) Message ID Message Text Explanation and Recommended Actions YKX100T TSO RC=48 Supplied parameters invalid Invalid parameters are specified. For details, see the reason code in the YKX199I message that will appear after this message.
Page 99
Table 28 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKX1x) (continued) Message ID Message Text Explanation and Recommended Actions Review the ROUTE and DAD parameters, route list definition file, and command device definition file you specified when executing the YKLOAD command. YKX199I TSO YKDELCMD command return The YKDELCMD command terminated with the return...
Page 100
Table 29 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKX2x) (continued) Message ID Message Text Explanation and Recommended Actions YKX208E MSG SC=48 CU() not valid hex The value specified in the CU parameter is not in hexadecimal format.
Page 101
Table 30 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY0x) (continued) Message ID Message Text Explanation and Recommended Actions message that was displayed before this message and then restart the Business Continuity Manager agent. termination-code (decimal number) 04: An attempt was made to start without using IKJEFT01.
Page 102
Table 30 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY0x) (continued) Message ID Message Text Explanation and Recommended Actions YKY021I CON A NAME/TOKEN WRITE ERROR The command cannot be executed because a OCCURRED, NAME/TOKEN write error occurred. The Business Continuity Manager agent will now stop.
Page 103
Table 31 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY1x) (continued) Message ID Message Text Explanation and Recommended Actions parameter-name Initialization parameter name parameter-value Initialization parameter value YKY130I CON SESSION NO.=session-number This message displays the TCP/IP session number. This message is followed by the TCP/IP session information.
Page 104
Table 31 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY1x) (continued) Message ID Message Text Explanation and Recommended Actions The direction of the data that was sent at the time displayed in YYYY/MM/DD hh:mm:ss SEND: Indicates that the data was sent.
Page 105
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions task-ID Number used to identify the processing task that output the message reason-for-disconnection FIN ACCEPT: A disconnection request (TCP-FIN) from the remote host was received.
Page 106
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions @ABORT: Forcibly releasing the connection @QUIT: Postprocessing response-code Code generated during the request shown as request-name event-code Event that occurred during the TCP/IP session local-IP-address...
Page 107
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions "LISTEN " "RECV " "SETSOCKOPT " "SOCKET " For details about the return code (RETCODE) for the request type and the error number (ERRNO), see the Communications Server IP API Guide.
Page 108
Table 32 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY3x) (continued) Message ID Message Text Explanation and Recommended Actions If the configuration file in which the error occurred still exists, delete it. Change the name of the temporary file to the name indicated by file.
Page 109
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) Message ID Message Text Explanation and Recommended Actions YKY600I CON INSUFFICIENT SPACE AVAILABLE. The area allocation by the Business Continuity maintenance-information Manager agent failed. The Business Continuity Manager agent will be terminated.
Page 110
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) (continued) Message ID Message Text Explanation and Recommended Actions abnormal termination code and reason code, see the MVS System Codes. reason-code For details about the reason code, see the TSO/E REXX Reference.
Page 111
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) (continued) Message ID Message Text Explanation and Recommended Actions Return code from the command that the Business Continuity Manager agent executed text Message (maintenance information) that was output by the command that the Business Continuity Manager agent executed YKY699I CON...
Page 112
Table 33 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY6x) (continued) Message ID Message Text Explanation and Recommended Actions called, relative to the top of the module CALLING-MODULE: Location where CALLING-MODULE was called, relative to the top of the module pppppppp pppppppp PSW during the abnormal...
Page 113
Table 34 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY7x) (continued) Message ID Message Text Explanation and Recommended Actions parameter-name Parameter name YKY715E XML An invalid value was specified for An invalid value was specified for parameter-name the parameter 'parameter-name' in in the XML request element element-name.
Page 114
Table 34 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY7x) (continued) Message ID Message Text Explanation and Recommended Actions YKY726E XML Configuration file error CGname The copy group definition information could not be 'cgname' error-type. acquired because the error indicated by error-type occurred in the configuration file.
Page 115
Table 34 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKY7x) (continued) Message ID Message Text Explanation and Recommended Actions Make sure that the specified consistency group exists in the copy group definition file. YKY999E TSO CON MFAgent cannot use this REXX exec A REXX script that cannot be used by Mainframe library.
Page 116
Table 35 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ0x) (continued) Message ID Message Text Explanation and Recommended Actions Check the ROUTE parameter, DAD parameter, route list definition file, and command device definition file specified in the YKLOAD command execution. YKZ099I TSO SC=0 command-name command return The command identified by command-name terminated...
Page 117
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions 14: YKFCSTAT 16: YKFREEZE 17: YKRUN 18: YKBLDCMD 19: YKQRYDEV 20: YKDELCMD yyy (character string) Maintenance information If this message is output when the log and trace are obtained, the RC is 0.
Page 118
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions yyy (string) Maintenance information If the REXX variable that the system tried to read does not exist, 36 is returned. Also, if this message is output while the YKLOAD command is being executed, the RC is 44.
Page 119
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions See the command code description in the explanation of the YKZ201E message. yyy (string) Maintenance information YKZ206E TSO RC=0 An I/O error occurred.
Page 120
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions If this message is displayed as maintenance information (1): ENTRYID ( eeeee ) for MSGID ( nnn ) is invalid eeeee, nnn: Maintenance information...
Page 121
Table 36 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ10x – YKZ20x) (continued) Message ID Message Text Explanation and Recommended Actions yyyy/mm/dd (string) GMT date hh:mm:ss.th (string) GMT time ttt (string) GMT time format xxx (decimal number) Command code of the command that was executing when the error occurred...
Page 122
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions Return code set by the NAME/TOKEN registration routine (IEANTCR) name (string) Name registered in the Name/Token service xxx (decimal number) Command code of the command...
Page 123
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions xxx (decimal number) Command code of the command that was executing when the error occurred See the command code description in the explanation of the YKZ201E message.
Page 124
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions Return code from the LOAD macro mmm (decimal number) Reason code from the LOAD macro (maintenance information) name (string) Load module name xxx (decimal number)
Page 125
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ220T MSG SC=36 Number of Route dad-id is invalid. The number of routes related to dad-id is invalid. RC=44 Check whether the device address domain ID specified in the YKLOAD command is invalid or...
Page 126
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions If this message is output while the YKLOAD command is being executed, the RC is 44. YKZ226E MSG SC=36 stemTCA_MAP=TRK not supported For the specified model, TRK cannot be specified for...
Page 127
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions Change the status of the copy pairs to a status that allows this command to be executed. device# Device number If the device cannot be identified,...
Page 128
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions Storage system model If this message is output while the YKLOAD command is being executed, the RC is 44. YKZ235E MSG SC=36 dad-id APID is null.
Page 129
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions Check the status of the volumes in the copy group, correct the YKRESYNC command parameter specification, and then re-execute the command.
Page 130
Table 37 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ21x – YKZ24x) (continued) Message ID Message Text Explanation and Recommended Actions If this message is output while the YKLOAD command is being executed, the RC is 44. Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) Message ID...
Page 131
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions xxx (decimal number) Command code of the command that was executing when the error occurred See the command code description in the explanation of the YKZ201E message.
Page 132
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions The corresponding device might not be configured or connected. When CC=0 and CSW=xxxxxx0000xxxx (DSB=00, CSB=00): The corresponding device might not be configured or connected.
Page 133
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions The corresponding device might not be configured or connected. When CC=0 and CSW=xxxxxx0000xxxx (DSB=00, CSB=00): The corresponding device might not be configured or connected.
Page 134
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions See the command code description in the explanation of the YKZ201E message. yyy (string) Maintenance information pair-index See the pair index description in the explanation of the YKE003E message.
Page 135
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions Error code For details about the error codes, “Storage System Sense Byte Information” (page 165). code4 (Hexadecimal number) Subcommand code xxx (decimal number) Command code of the command...
Page 136
Table 38 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ25x) (continued) Message ID Message Text Explanation and Recommended Actions See the command code description in the explanation of the YKZ201E message. yyy (string) Maintenance information YKZ259E MSG SC=48 This product is already executing.
Page 137
Table 39 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ26x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ263E MSG CON A YKLOGnn I/O error. (text, An I/O error occurred in YKLOG01 or YKLOG02. SC=0 RC=0 cp=xxx:yyy) YKLOGnn YKLOG01 or YKLOG02...
Page 138
Table 39 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ26x) (continued) Message ID Message Text Explanation and Recommended Actions YKLOG01 or YKLOG02 nnn (decimal number) Return code from the DEVTYPE macro mmm (decimal number) Reason code from the DEVTYPE macro xxx (decimal number) Command code of the command...
Page 139
Table 40 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ27x) Message ID Message Text Explanation and Recommended Actions YKZ270E MSG SC=36 Duplicate logical paths exist. The logical path definitions for index1 and index2 RC=36 (index1, index2) are duplicated.
Page 140
Table 40 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ27x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ273E MSG SC=36 No path to be operated exist within No paths to be operated exist within the range RC=36 the range specified by the supplied specified by the parameter.
Page 141
Table 40 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ27x) (continued) Message ID Message Text Explanation and Recommended Actions IFType are X'11' or higher). Also, if scanning was not performed after the storage system microcode was replaced, perform another scan. YKZ277W MSG SC=4 Some paths are in the NOPATH There is a logical path without a physical path...
Page 142
Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ28x) (continued) Message ID Message Text Explanation and Recommended Actions models (or later) where the first two digits of the IFType are X'04' or higher. YKZ282E MSG SC=36 Primary device IFType does not Cnt Ac-J Z cannot be used on a storage system that RC=36...
Page 143
Table 41 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ28x) (continued) Message ID Message Text Explanation and Recommended Actions To execute one of these commands against a logical path, correct the configuration file and then execute the YKLOAD command.
Page 144
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions Previous log dataset (YKLOG01 or YKLOG02) YKLOGnn New log dataset (YKLOG01 or YKLOG02) Job name xxx (decimal number) Command code for the command that was executing when the log dataset was switched...
Page 145
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions message will appear until the registration has completed normally. Also, if you execute the YKQUERY command to obtain the status while the copy pair of the copy group containers with EXCTG ID specified is dissolved, the YKZ296E message sometimes appears when the...
Page 146
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions The journal group number specified by the C/T group ID or the sub C/T group ID (00-FF) m (decimal number) Mirror ID (0-3) e (decimal number)
Page 147
Table 42 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ29x) (continued) Message ID Message Text Explanation and Recommended Actions it was not found in the configuration file. JNLG (string) The journal type registered to the storage system (the journal type of the storage system, rather than of the definition) R-JNL: Journal of the secondary...
Page 148
Table 43 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ3x) (continued) Message ID Message Text Explanation and Recommended Actions For details about registering a user SVC, see the HP P9000 for Business Continuity Manager Software Installation Guide. YKZ301E CON RC=128 The task is not authorized to execute The task is not authorized to execute a CLI command.
Page 149
Table 43 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ3x) (continued) Message ID Message Text Explanation and Recommended Actions For details, see the TSO/E REXX User's Guide. n (decimal number) Reason code from the REXX service. For details, see the TSO/E REXX User's Guide.
Page 150
Table 43 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ3x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ350T TSO RC=16 Invalid parameters have been Invalid parameters have been specified. specified. YKZ351E TSO RC=16 No error code has been specified. No error code has been specified.
Page 151
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions The copy type specified for the copy group YKZ401E MSG SC=48 Some of the storage systems do not The storage system which the command is issued RC=48 support param.
Page 152
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions configure a container, use different numbers in one of the pairs of C/T group ID and sub C/T group ID which describe the journal group number.
Page 153
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions Generation ID (00-FF) aa (decimal number) Status of ATTIME suspension (0-4) 0: No ATTIME suspend time has been set. 1: The ATTIME suspend time has been set, but suspension has not been performed yet.
Page 154
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions ii (hexadecimal number) consistency group ID for BC Z (00-7F) jj (hexadecimal number) The journal group number specified for the sub consistency group ID for the Cnt Ac-J Z that links with BC Z (00-FF) gg (hexadecimal number)
Page 155
Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ40x) (continued) Message ID Message Text Explanation and Recommended Actions SS.NNNNNN: Second YKZ409E MSG SC=24 The timeout limit expired during the The suspend processing started when the timeout RC=24 wait for the reservation time of the period elapsed because this period elapsed before...
Page 156
Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ41x) (continued) Message ID Message Text Explanation and Recommended Actions used in the copy group (minimum) If this message is output while the YKLOAD command is being executed, the RC is 44. The Errorlevel for Cnt Ac-J Z can be used in a storage system where the version of the storage system support function is X'12' or higher.
Page 157
Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ41x) (continued) Message ID Message Text Explanation and Recommended Actions YKZ414E MSG SC=36 Copygroup SUPFnc does not support The function indicated by parameter-name cannot RC=48 parameter-name. be used. Use a device that supports the parameter-name function or configuration.
Page 158
Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ41x) (continued) Message ID Message Text Explanation and Recommended Actions 2DC configuration with HyperSwap and Cnt Ac-J Z ◦ XP24000/XP20000 disk array Version of the storage system support function: X'22' or higher ◦...
Table 45 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions (Message ID YKZ41x) (continued) Message ID Message Text Explanation and Recommended Actions systems with the following versions of the storage system support function: XP12000/XP10000 disk array Version of the storage system support function: X'11' or higher XP24000/XP20000 disk array Version of the storage system support function:...
<e>: Serial number of the secondary storage system <f>: Consistency delta value <g>: Consistency time YK8316I PRT REPORT STATS: COPY GROUP : <a> PREFIX : <b> DAD-ID : <c> TYPE : <d> --- PRI %S ---- - SEC %S -- --- TIMERS --- PRI- SEC-...
<d>: Copy group type <e>: Master journal group ID <f>: Restore journal group ID <g>: Serial number of the primary storage system <h>: Serial number of the secondary storage system <i>: Data transfer rate (Kbps) between the main control unit and the remote control unit <j>: Master journal volume metadata percent usage <k>: Master journal volume data percent usage <l>: Restore journal volume metadata percent usage...
<cgmonstat>: Copy group monitoring status (ACTIVE or INACTIVE) <cgsastat>: Copy group startup status to be checked for starting BCM Monitor <cgsaact>: Startup action executed if the copy pair status for starting BCM Monitor is different from the specified startup status <cgsaopt>: Option information of the CGSTARTUPSTATUS parameter <status>...
Identifying the Volume Serial Number from the Configuration File Use the following steps to acquire the volume serial number from the configuration file: Count the CopyPair tags from the beginning of the file and identify the CopyPair tag. The SerialNum under the identified CopyPair tag is the volume serial number to be processed. Version 2.0 or later: Count the CopyGroupContainer tags from the beginning of the file and identify the CopyGroupContainer tag.
2 Storage System Sense Byte Information This chapter describes storage system sense byte information (error codes) contained in messages that are output by Business Continuity Manager. Details of Error Codes This section lists the details on the storage system sense byte information (error codes) that are output to messages.
Page 166
Table 47 Details of Error Codes 20xx – 22xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others the specified BC Z copy pair does not meet all of the following conditions: The S-VOL is part of a delta resync pair The delta resync pair is in the...
Page 167
Table 47 Details of Error Codes 20xx – 22xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others for the S-VOL of the BC Z pair is being expanded. A copy pair could not be created Output Not output 20B4...
Page 168
Table 47 Details of Error Codes 20xx – 22xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair could not be created for Output Not output 20D7 one of the following reasons: The S-VOL of the specified BC Z copy pair is being used for Compatible FlashCopy.
Page 169
Table 48 Details of Error Codes 23xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others information on combinations, see the Business Copy for Mainframe Systems User Guide for the disk array.
Page 170
Table 48 Details of Error Codes 23xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A BC Z copy pair status cannot be Output Not output 2332 transitioned because the maximum multiplicity of the copy pairs for the P-VOL was exceeded.
Page 171
Table 48 Details of Error Codes 23xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A BC Z copy pair status cannot be Output Not output 234A changed because the volume specified to be the S-VOL is already the P-VOL of a BC Z copy pair or the one for FlashCopy.
Page 172
Table 48 Details of Error Codes 23xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others because all of the following conditions exist: The specified P-VOL is an internal volume. The specified S-VOL is an external volume.
Page 173
Table 48 Details of Error Codes 23xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others because the specified S-VOL is the P-VOL of a Cnt Ac-S Z copy pair. The command could not be executed Output Not output 23A0...
Page 174
Table 48 Details of Error Codes 23xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be executed Output Not output 23F5 because the ATTIME suspend time is already set.
Page 175
Table 49 Details of Error Codes 36xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others Registration to EXCTG has failed Not output Output Not output 3642 because the journal group attribute is incorrect.
Page 176
Table 50 Details of Error Codes 37xx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output 3703 resynchronized (with the PREPARE parameter) because the journal volume has PIN data.
Page 177
Table 50 Details of Error Codes 37xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The reason might be one of the following: The specified M-JNL group or R-JNL group does not allow the status to be changed.
Page 178
Table 51 Details of Error Codes 46xx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output 4600 made. Possible reasons include one or both of the following: The serial number of the primary storage system in the parameter...
Page 179
Table 51 Details of Error Codes 46xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others specified arbitration command device number (a non-existent value), EXCTG ID, mirror ID, journal group number, or serial number is incorrect.
Page 180
Table 51 Details of Error Codes 46xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command device cannot be Not output Output Not output 461E defined. The reason might be one of the following: The command device is executing a remote control command.
Page 181
Table 51 Details of Error Codes 46xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A delta resync cannot be executed Not output Output Not output 4650 because volumes are specified within the operational range.
Page 182
Table 51 Details of Error Codes 46xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others When changing the timer type from Local to System, you need to suspend the Cnt Ac-J Z copy pair. If the CAJ ATTIME suspend time has already been set, perform the following procedure to set the CAJ...
Page 183
Table 52 Details of Error Codes 47xx – 49xx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-S Z or TCA copy pair Output Not output 47A3 cannot be suspended because output SVOL(PERMIT) or Reverse Resync is not supported.
Page 184
Table 53 Details of Error Codes 4Axx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The C/T group ID defined in the Not output Output Not output 4A30 TCA copy group, and the C/T group ID set by the copy pair do not match.
Page 185
Table 53 Details of Error Codes 4Axx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be executed Output Not output 4A8E because the status of the Cnt Ac-S Z output or TCA copy pair is being changed.
Page 186
Table 54 Details of Error Codes 4Bxx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair cannot be Output Not output 4B02 resynchronized because the copy output pair is in a status that cannot be changed.
Page 187
Table 54 Details of Error Codes 4Bxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others specified cannot be dissolved because the copy pair status does not allow the status to be changed. The reason might be one of the following: The specified volume is not in a...
Page 188
Table 54 Details of Error Codes 4Bxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others specified. The reason might be one of the following: The specified volume is not in a Cnt Ac-S Z copy group with a C/T group ID specified.
Page 189
Table 54 Details of Error Codes 4Bxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A TCA copy pair cannot be made Not output Output Not output 4BA9 because the specified CTID is not registered in the storage system.
Page 190
Table 55 Details of Error Codes 50xx – 6Axx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The corresponding volume is online. The corresponding volume is being used by another program product such as BC Z, Cnt Ac-S Z, TCA, Cnt Ac-J Z or Compatible FlashCopy.
Page 191
Table 55 Details of Error Codes 50xx – 6Axx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair cannot be made. The Output Not output 69F3 reason might be one of the following: The storage system serial number of the P-VOL is...
Page 192
Table 55 Details of Error Codes 50xx – 6Axx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be Not output Output Not output 6A07 executed because the corresponding volume is not the P-VOL of a TCA copy pair or it is a Non Gen'ed volume.
Page 193
Table 56 Details of Error Codes 7Fxx – 8Cxx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command cannot be executed Not output Output 7F86 because no program product for copying is installed.
Page 194
Table 56 Details of Error Codes 7Fxx – 8Cxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair cannot be made because the same C/T group ID is set in both the MCU and RCU. The specified C/T group ID is not registered.
Page 195
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair cannot be made. The Output Not output Output 8D10 reason might be one of the output following: An inter-CU logical path has not...
Page 196
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others For details, see error code 2310. The charging limit of the program product was exceeded. The copy pair is in the Pending status.
Page 197
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others For details, see error code 2310. The P-VOL is online. The charging limit of the program product was exceeded.
Page 198
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others include one or more of the following: The status of the copy pair does not allow the status transition. For details, see error code 2310.
Page 199
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The status is invalid. The status of the copy pair is being changed. A BC Z copy pair cannot be Output Not output 8D2A...
Page 200
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command cannot be executed Not output Output Not output 8D42 because the volume specified as a command device is a volume used in the open system.
Page 201
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be Not output Output Not output 8D52 executed because the logical volume of the specified volume is blocked.
Page 202
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others storage system serial number or SSID of RCU. The S-VOL number in the parameter and bootup volume number do not match.
Page 203
Table 57 Details of Error Codes 8Dxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A TCA C/T group cannot be Not output Output Not output 8D79 deleted. Possible reasons include one or more of the following: The C/T group ID is incorrect.
Page 204
Table 58 Details of Error Codes 8Fxx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output 8F00 made because the specified volume is an external volume.
Page 205
Table 58 Details of Error Codes 8Fxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output 8F24 made because a path has not been established between the devices.
Page 206
Table 58 Details of Error Codes 8Fxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others does not allow the status transition. (For example, the specified volume has already been made as a BC Z copy pair and cannot be used for this combination.) A Cnt Ac-J Z copy pair cannot be...
Page 207
Table 59 Details of Error Codes C0xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others Cnt Ac-S Z or TCA parameter does not match the storage system serial number or SSID of the RCU. The serial number or SSID of the Output Not output...
Page 208
Table 59 Details of Error Codes C0xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The P-VOL number in the Cnt Ac-S Output Not output C06D Z or TCA parameter does not output match the bootup volume number.
Page 209
Table 59 Details of Error Codes C0xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be Output Not output C0C7 executed because it is already in output the SIMPLEX status.
Page 210
Table 60 Details of Error Codes C1xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The command could not be Not output Output C12A executed because the output device-identifying code of an RCU for which path deletion is specified is invalid, or because the RCU type (FIBRE/ESCON) is invalid.
Page 211
Table 60 Details of Error Codes C1xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair cannot be suspended Output Not output C194 because the S-VOL status is being output changed.
Page 212
Table 61 Details of Error Codes C2xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair cannot be suspended Output Not output C23E because the specified copy pair is output in the Pending status.
Page 213
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others be made because the Disaster Recovery Extended program product has not been installed in the RCU. A copy pair cannot be made Output Not output...
Page 214
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others Formatting of the logical volume is Output Not output C31D being performed on the P-VOL. output The P-VOL is in the READ ONLY Output...
Page 215
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The S-VOL has PIN data. Output Not output C336 output The S-VOL is in the Reserve status. Output Not output C337...
Page 216
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The subsystem level cache of the Output Not output C37C RCU is not valid. output The RCU is not NVS ON.
Page 217
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The S-VOL is online. Output Not output C3A5 output The specified SSID, or CU number Output Not output C3A6...
Page 218
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others When the P-VOL of a Cnt Ac-S Z Output Not output C3C0 or TCA copy pair is also the S-VOL output of a BC Z copy pair, both S-VOLs must be a copy pair in a one-to-one...
Page 219
Table 62 Details of Error Codes C3xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The specified SSID, or CU number Output Not output C3D3 of the RCU is incorrect. output The specified S-VOL cannot be Output...
Page 220
Table 63 Details of Error Codes CBxx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A copy pair cannot be made Not output Output Not output CB10 because there was an attempt to make a copy pair for both directions with the same C/T group A copy pair cannot be added to a...
Page 221
Table 63 Details of Error Codes CBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others satisfies one of the following conditions: The S-VOL is being used for FlashCopy. The S-VOL is being used for FlashCopy SE.
Page 222
Table 64 Details of Error Codes DBxx – E8xx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair status Not output Output Not output DB02 cannot be changed because the status transition is not allowed.
Page 223
Table 64 Details of Error Codes DBxx – E8xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output E86B dissolved because the specified volume is not a Cnt Ac-J Z copy...
Page 224
Table 64 Details of Error Codes DBxx – E8xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output E882 made because the emulation type for the volumes comprising the...
Page 225
Table 64 Details of Error Codes DBxx – E8xx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output E89B made because the status from the previous connection with another...
Page 226
Table 65 Details of Error Codes EAxx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others The Cnt Ac-J Z copy pair cannot Not output Output Not output EA00 be operated for each EXCTG because of the following reasons: The JNLG specified in the copy group is not registered in the...
Page 227
Table 65 Details of Error Codes EAxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output EA18 resynchronized because the copy pair is not in the suspend status.
Page 228
Table 65 Details of Error Codes EAxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output EA36 suspended because the R-JNL group is not in the Active status.
Page 229
Table 65 Details of Error Codes EAxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output EAA2 made because the charging limit of Cnt Ac-J Z in the MCU has been exceeded.
Page 230
Table 66 Details of Error Codes EBxx Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair status Not output Output Not output EB02 cannot be changed because the specified journal group number is invalid.
Page 231
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others differs from the secondarystorage system of the existing copy pair. Therefore, a Cnt Ac-J Z copy pair cannot be made.
Page 232
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others M-JNLG differs from that for R-JNLG. A Cnt Ac-J Z copy pair cannot be Not output Output Not output EB50...
Page 233
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output EB64 made because the charging limit of the program product has been exceeded.
Page 234
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others copy pair, and is being resynchronized in the reverse direction or is being shared with the Cnt Ac-S Z copy pair. The specified S-VOL is a Reserve volume.
Page 235
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair status Not output Output Not output EBA0 cannot be changed because the specified S-VOL is not installed.
Page 236
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A Cnt Ac-J Z copy pair cannot be Not output Output Not output EBD9 made because the charging limit of Cnt Ac-S Z in the RCU has been exceeded.
Page 237
Table 66 Details of Error Codes EBxx (continued) Error Error Details Type of Error Code BC Z Cnt Ac-S Z Cnt Ac-J Z PATH Others A delta resync pair cannot be Not output Output Not output EBF3 made because the CAJ ATTIME suspend time is already set.
3 Support and other resources Contacting HP For worldwide technical support information, see the HP support website: http://www.hp.com/support Before contacting HP, collect the following information: Product model names and numbers Technical support registration number (if applicable) Product serial numbers Error messages Operating system type and revision level Detailed questions Subscription service...
Page 239
MVS System Codes, GC28- 1 780 MVS System Commands, GC28- 1 781 MVS Programming: Assembler Services Reference, GC28- 1 910 Communications Server: IP User's Guide and Commands, GC31-8514 Program Directory for IBM Library for REXX on zSeries Alternate Library, GI10-3243 DFSMSdfp Utilities, SC26-7343 MVS Initialization and Tuning Reference, SC28- 1 752 SecureWay Security Server RACF Security Administrator's Guide, SC28- 1 915...
http://www.hp.com/support/manuals In the Storage section, click Storage Software and then select a product. HP websites For additional information, see the following HP websites: http://www.hp.com http://www.hp.com/go/storage http://www.hp.com/service_locator http://www.hp.com/support/manuals http://www.hp.com/support/downloads http://www.hp.com/storage/whitepapers Conventions for storage capacity values P9000 disk arrays use the following values to calculate physical storage capacity values (hard disk drives): 1 KB (kilobyte) = 1,000 bytes 1 MB (megabyte) = 1,000...
Page 241
Table 67 Document conventions (continued) Convention Element Monospace text File and directory names System output Code Commands, their arguments, and argument values Monospace, italic text Code variables Command variables Monospace, bold text Emphasized monospace text WARNING! Indicates that failure to follow directions could result in bodily harm or death. CAUTION: Indicates that failure to follow directions could result in damage to equipment or data.
4 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hp.com). Include the document title and part number, version number, or the URL when submitting your feedback.
Glossary Application programming interface. BC Manager A generic name for the following products: P9000 for Business Continuity Manager Software HP StorageWorks P9000 for Business Continuity Manager Extended CT Group P9000 for Bus Continuity Manager Universal Replicator 4x4 Extended CT Software Command control address.
Page 244
M-JNL Master journal. Mainframe Agent HP Device Manager Mainframe Agent. Main control unit. Missing interrupt handler. P-VOL Primary volume. PPRC Peer-to-peer remote copy. Program status word. R-JNL Restore journal. RACF Resource access control facility. Remote control unit. RECFM Record format. REXX Restructured extended executor.