Table 68 Error codes (part code 8105) (continued)
Part
Error
Code
Number
8105
5030
8105
5060
8105
5061
8105
5062
8105
551 1
8105
5566
8105
5650
8105
5651
8105
5652
8105
5660
8105
5700
8105
5701
8105
5702
8105
5705
8105
5710
8105
571 1
8105
5712
8105
5720
8105
5721
8105
5730
8105
5731
8105
5740
8105
5741
8105
5742
8105
5743
290 Message (part code group 8nnn)
Error Message
The spreadsheet has not been changed
at all.
The length of the character string is
invalid.
The number of lines is invalid.
The size of the CSV file is invalid.
Configuration File Loader is not installed.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
The length of the letter string is invalid.
The number of lines is invalid.
The size of the CSV file is invalid.
The Thin Provisioning volume is not
associated with a pool. Associate the
Thin Provisioning and a pool first.
The file format is invalid.
The header is invalid.
There is no tag.
Configuration File Loader is not installed.
The specified CHA does not exist.
The specified port does not exist.
The numbers specified for CU and LDEV
(CU: LDEV) are invalid.
You set the same tag name more than
once.
The parameter is invalid.
Duplicate definition error.
The current information is invalid.
There is a difference between the current
CHA and the specified CHA.
There is a difference between the current
port and the specified port.
The setting cannot be performed,
because an invalid Channel Speed value
is set to the specified port.
There is a difference between the current
CU:LDEV and the specified CU:LDEV.
Recommended Action
Change the configuration at least one
line in the spreadsheet.
One line can have up to 127 characters.
The CSV file can have up to 70,000
lines.
Check the CSV file.
Install Configuration File Loader.
If this problem persists, please contact
HP Technical Support.
One line can have up to 127 letters.
The spreadsheet can have up to 70,000
lines.
Check the CSV file.
Associate the Thin Provisioning volume
with a pool, then retry the operation.
Enter the text file.
Check the version information of the first
row.
Write at least one tag.
Install the Configuration File Loader.
Correct the name of CHA.
Correct the name of the port.
Correct the numbers for CU and LDEV
(CU: LDEV).
Define each tag once in a sheet.
Correct the invalid parameter.
Write one definition only in each tag.
Correct the current information.
Correct the name of the CHA.
Correct the name of the port.
The Channel Speed value is invalid.
Specify a correct value.
Correct the CU and LDEV.
Severity
Level
W
E
E
E
W
E
W
W
W
E
E
E
E
W
W
W
W
W
W
W
W
W
W
W
W