Table 56 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
68784
The Pairresync operation failed because
the specified primary data volume was
one of the following.
The volume was not used by
Continuous Access Synchronous or
External Storage Access Manager.
The volume was used by Continuous
Access Synchronous or External
Storage Access Manager, but the pair
status was not PSUS or PSUE.
6505
68804
The operation failed because the
specified M-VOL is used as FICON(R)
Data Migration.
6505
68805
The operation failed because the
specified M-VOL is used as FICON(R)
Data Migration.
6505
6881 1
The specified volume cannot be used as
a journal volume because it is used by
FICON(R) Data Migration.
6505
68812
A pair could not be created because the
specified secondary data volume was a
Thin Provisioning or Thin Provisioning Z
volume whose capacity was being
changed.
6505
68813
A pair could not be created because the
specified primary data volume was a
Thin Provisioning or Thin Provisioning Z
volume whose capacity was being
changed.
6505
68815
The pair cannot be released because the
specified volume is used as the pair
volume of Continuous Access
Synchronous or External Storage Access
Manager.
6505
68842
The operation failed, because the
specified secondary data volume was a
volume of Thin Provisioning or Thin
Provisioning Z whose zero data was
being discarded.
6505
68843
The operation failed, because the
specified primary data volume was a
volume of Thin Provisioning or Thin
Provisioning Z whose zero data was
being discarded.
6505
68848
The operation failed because the pool
associated with the Thin Provisioning
volume or Thin Provisioning Z volume
that was specified as the primary data
volume was being initialized.
6505
68849
The operation failed because the pool
associated with the Thin Provisioning
Recommended Action
The master journal group of the specified
primary data volume runs on the 2DC
configuration in which the Continuous
Access Synchronous or External Storage
Access Manager cooperates.
Delete the Continuous Access
Synchronous or External Storage Access
Manager pair volume or suspend it.
Check the status of the specified M-VOL
from the host or the SVP.
Check the status of the specified R-VOL
from the host or the SVP.
Specify a volume that is not used by
FICON(R) Data Migration.
Check each capacity of the primary data
volume and the secondary data volume
after the capacity change of secondary
data volume ends. Plan a combination
of volumes for pair creating.
Check each capacity of the primary data
volume and the secondary data volume
after the capacity change of primary
data volume ends. Plan a combination
of volumes for pair creating.
The specified volume runs on the 2DC
configuration in which the Continuous
Access Synchronous or External Storage
Access Manager cooperates.
Release the pair of Continuous Access
Synchronous or External Storage Access
Manager, then retry the operation.
Retry the operation after the completion
of discarding zero data on the specified
volume.
Retry the operation after the completion
of discarding zero data on the specified
volume.
Wait until the initializing processing is
completed, and then retry the operation.
Wait until the initializing processing is
completed, and then retry the operation.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W