Table 53 Error codes (part code 6005) (continued)
Part
Error
Error Message
Code
Number
6005
68793
The Reverse Resync operation failed
because the status of the specified
volume was not SSWS.
6005
68794
The operation failed because the path
from the RCU to the MCU did not exist.
6005
68795
The operation failed. The shared
memory might be insufficient.
Please contact HP Technical Support.
6005
68796
The operation failed. The operation
cannot be accepted in the pair status
of the specified volume.
6005
68812
A pair could not be created because
the specified R-VOL was a Thin
Provisioning volume or Thin
Provisioning Z volume whose capacity
was being changed.
6005
68813
A pair could not be created because
the specified M-VOL was a Thin
Provisioning volume or Thin
Provisioning Z volume whose capacity
was being changed.
6005
68816
A pair cannot be created because the
specified volume is used as a primary
data volume of the Continuous Access
Journal.
6005
68817
The specified R-VOL was a pair volume
of the Continuous Access Journal.
A pair could not be created because
"Cylinder" was set to the "Difference
Management."
6005
68826
The operation failed, because the
External Storage function was not
installed.
Recommended Action
External Storage Access
Manager pair volume.
Refresh the window, and
confirm whether the status of
the specified volume is
SSWS.
Create a path from the RCU
to the MCU.
Contact HP Technical
Support and check the
shared memory.
Refresh the window, and
confirm the pair status of the
specified volume.
Check each capacity of the
M-VOL and the R-VOL after
the capacity change of
R-VOL ends, and plan a
combination of volumes for
pair creating.
Check each capacity of the
M-VOL and the R-VOL after
the capacity change of
M-VOL ends, and plan a
combination of volumes for
pair creating.
The specified volume is a
primary data volume of the
Continuous Access Journal,
which runs on the 2DC
configuration in which the
Continuous Access
Synchronous or External
Storage Access Manager
cooperates. Specify another
volume.
The RCU runs on the 2DC
configuration in which the
Continuous Access Journal
cooperates.
Set "Track" to the
"Difference Management,"
then retry the operation.
Install the External Storage,
then retry the operation.
Severity Level
W
W
E
W
W
W
W
W
W
Part code 6005 175