HP XP P9500 Manual page 198

Hp p9000 remote web console messages (av400-96401, october 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 56 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
58075
6505
58078
6505
58079
6505
58080
6505
58081
6505
58082
6505
58083
6505
58084
6505
58085
6505
58086
6505
58087
6505
58088
6505
58089
6505
58090
6505
58091
6505
58092
198 Message (part code group 6nnn)
Error Message
The specified serial number is incorrect.
The specified volume does not exist or
is unusable.
The specified primary data volume
cannot be used as a secondary volume
due to the settings of Volume Retention
or Data Retention.
A Concurrent Copy operation is in
progress on the specified primary data
volume.
The specified primary data volume
belongs to an access group or a pool
group of Volume Security for Mainframe.
The specified consistency group is
already used.
The specified master journal is not
registered.
The specified primary data volumes
cannot be paired with another volume,
because the primary data volume is used
as a journal volume.
The specified primary data volume is not
registered in the specified journal.
The specified master journal is not
registered.
The emulation type of the specified
primary data volume is incorrect due to
one of the following reasons:
The emulation type is not supported.
The combination of emulation types
within the journal is incorrect.
The combination of emulation types
between journals is incorrect.
The specified mirror ID differs from the
registered mirror ID.
Check the combination of the master
journal and the mirror ID.
No more remote subsystems can be
registered.
The SLPR number of the specified data
volume does not match the SLPR number
of the journal volume in the specified
journal.
The specified primary data volume is
already registered.
No more pairs can be registered in the
specified master journal.
Recommended Action
Check the specified serial number.
Check the status of the specified volume.
Check the status of the specified primary
data volume in the Volume Retention
window or the Data Retention window.
Check the status of the specified primary
data volume.
Check the status of the specified volume
in the Volume Security for Mainframe
window.
Check the consistency group status in the
Continuous Access Journal window of
the local and the remote storage systems.
Check the status of the specified master
journal.
Check the status of the specified primary
data volume.
Check the data volumes in the specified
journal.
Check the status of the specified master
journal.
Check the emulation type of the specified
primary data volume.
Check the specified mirror ID.
Reduce the number of registered remote
storage systems, then retry the operation.
Check the SLPR number of the specified
data volume and the journal volume in
the journal.
Check the status of the specified primary
data volume.
Check the number of pairs in the
specified master journal.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
E
W
W

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000P9500

Table of Contents