Table 65 Error codes (part code 7105) (continued)
Part
Error
Code
Number
7105
58533
7105
58534
7105
58535
7105
58536
7105
58572
7105
58573
7105
58575
7105
58585
7105
58630
7105
58631
7105
58632
7105
68743
7105
68744
7105
68745
7105
68746
274 Message (part code group 7nnn)
Error Message
The operation failed, because the
specified S-VOL was a journal volume.
The operation failed, because the
specified T-VOL was a journal volume.
The reserve volume setting failed
because the specified volume was a
journal volume.
The operation failed because the
specified T-VOL was a data volume of
Continuous Access Journal Z.
An error occurred on the DKC side.
This function is not supported.
An error occurred while connecting to
the subsystem.
The operation failed because the CU
group of the specified volume is not
supported.
The operation failed because the
specified S-VOL was used by Delta
resync of Continuous Access Journal Z.
The operation failed because the
specified T-VOL was used by Delta
resync of Continuous Access Journal Z.
The reserve volume setting failed
because the specified volume was used
by Delta resync of Continuous Access
Journal Z.
The command has been rejected,
because Quick Format is performed on
the specified S-VOL.
The command has been rejected,
because Quick Format is performed on
the specified T-VOL.
FICON(R) Data Migration Source Volume
is specified as a T-VOL. FICON(R) Data
Migration Source Volume cannot be used
as a T-VOL.
The command has been rejected
because the pair uses FICON(R) Data
Migration Source Volume.
Recommended Action
Release the journal volume setting or
specify another volume.
Release the journal volume setting or
specify another volume.
Release the journal volume setting or
specify another volume.
Check the requirements for using the
volume with Continuous Access Journal
Z.
If this problem persists, please contact
HP Technical Support.
Check if the DKCMAIN and SVP
microcode versions are mismatched.
If this problem persists, please contact
HP Technical Support.
Volumes that do not belong to CU group
0 are currently not supported. Specify
another volume.
The command cannot be executed in the
current status of Continuous Access
Journal Z pair.
See the section "Sharing Business Copy
Z volumes" in the HP P9000 Business
Copy for Mainframe Systems User Guide
for the relation between the state of
Continuous Access Journal Z pair and
the Business Copy Z operations.
The P-VOL of Continuous Access Journal
Z pair for Delta resync cannot be
specified as S-VOL. Specify another
volume.
The P-VOL of Continuous Access Journal
Z pair for Delta resync cannot be
specified as a reserved volume.
Specify another volume.
Retry the operation after the Quick
Format has completed.
Retry the operation after the Quick
Format has completed.
FICON(R) Data Migration source volume
cannot be used as a T-VOL. Use other
volumes.
The specified pair cannot be operated
because the pair uses FICON(R) Data
Migration source volume.
Severity
Level
W
W
W
W
E
E
E
W
W
W
W
W
W
W
W

Advertisement