HP XP P9500 Manual page 189

Hp p9000 remote web console messages (av400-96401, october 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 56 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
8708
The pair status of the secondary data
volume is incorrect.
6505
8709
Remote Copy operation was rejected.
6505
8710
The pair status of the specified data
volume is incorrect.
6505
871 1
The specified parameter is incorrect.
6505
8712
The operation was rejected due to a
'FREEZE' state.
6505
8713
The port group already exists on the
specified port.
6505
8714
An internal error occurred.
6505
8715
The number of paths is incorrect.
6505
8719
The serial number or the controller ID of
the remote subsystem is incorrect.
6505
8720
The number of registered remote
subsystems already reached the
maximum (that is, 64).
6505
8721
Path creation has not finished yet.
6505
8722
Path creation failed.
6505
8723
The Edit Path operation was rejected
because the specified path is the last
path of some Remote Copy pairs.
6505
8724
The specified number of paths is less
than the minimum number specified in
the DKC Option window.
Recommended Action
Refresh the window, and check the pair
status. If possible, retry the operation on
the secondary data volume.
Replace the channel adapter, then retry
the operation.
Refresh the window, and check the pair
status of the pair. If the pair status can
be manipulated, retry the operation.
Check the port number, ID, and LUN of
the storage system.
If you are performing a path operation,
retry the operation after the FREEZE
status is released.
If you are performing a pair operation,
check the DKC status, wait until the SCP
time elapses, then retry the operation.
Exchange the port type after deleting the
group setting.
Please contact HP Technical Support.
Ensure that the number of paths is
correct, then retry the operation. If the
problem persists, please contact HP
Technical Support.
Check the serial number and the
controller ID of this remote storage
system and already registered remote
storage systems, then specify the correct
values.
If the specified values are correct, check
the cable connection of the remote
storage system. If the problem persists,
please contact HP Technical Support.
Reduce the number of registered remote
storage systems, then retry the operation.
Check the path connections between the
local and the remote storage systems,
then retry the operation.
Check the path connections between the
local and the remote storage systems,
then retry the operation.
Add another path, or delete all pairs on
the remote storage system. Then retry the
operation.
Check the number of paths.
Severity
Level
W
E
W
W
W
W
E
W
W
W
W
W
W
W
Part code 6505 189

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000P9500

Table of Contents