Table 56 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
58345
The Add Pair (Paircreate) operation
failed due to one of the following
reasons:
The IO suppression mode of the
specified secondary data volume is
enabled.
The microcode version of the
secondary storage system does not
support external volumes.
6505
58346
The Paircreate operation failed because
a Data Retention VMA was set up on the
specified secondary data volume.
6505
58347
The Add Pair (Paircreate) operation
failed because of a Volume Security for
Mainframe setting on the specified
secondary data volume.
6505
58348
The Paircreate operation failed because
a Data Retention VMA was set up on the
specified primary data volume.
6505
58349
The Add Pair operation failed because
the specified primary data volume had
a Protect attribute set by Volume
Retention.
6505
58352
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was one of the following:
a Business Copy S-VOL
a Business Copy Z T-VOL
a reserved volume
6505
58353
The operation failed because the
specified secondary data volume was
one of the following:
An S-VOL of Business Copy.
A T-VOL of Business Copy Z or
Compatible FlashCopy.
A reserved volume of Business Copy
or Business Copy Z.
A P-VOL of Business Copy in Swap
or Reverse Copy status.
An S-VOL of Business Copy Z in
Swap or Reverse Copy status.
A P-VOL of Business Copy used in
conjunction with Continuous Access
Synchronous.
A P-VOL of Business Copy used in
conjunction with External Storage
Access Manager.
An S-VOL of Business Copy Z or
Compatible FlashCopy used in
conjunction with Continuous Access
Synchronous Z.
A volume used by XP Flex Copy.
Recommended Action
Be sure that IO suppression mode of the
specified secondary data volume is
enabled on the Universal Volume Mgr
window. If the IO suppression mode is
disabled, check the microcode version
of DKCMAIN of the secondary storage
system, and contact HP Technical
Support.
From the Data Retention window, check
the settings of the specified secondary
data volume.
Check the setting of the specified
secondary data volume in the Volume
Security for Mainframe window.
From the Data Retention window, check
the settings of the specified primary data
volume.
From the Volume Retention window,
check the settings of the specified
primary data volume.
Check the status of the primary data
volume in the Business Copy window or
the Business Copy Z window.
Extract the possible combination of
program products from the combinations
of program products described in the
message. Check the status of the
secondary data volume from the window
of the program product. To use the Thin
Provisioning volume as a secondary data
volume, release the attribute of the
program product combined with the Thin
Provisioning volume, and then retry the
operation.
Severity
Level
W
W
W
W
W
W