Table 56 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
58485
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was one of the following:
the specified volume was a P-VOL of
Snapshot and was in Reverse Copy
status.
the specified volume was an S-VOL
of Snapshot.
6505
58486
The Paircreate operation failed because
the specified primary data volume was
a V-VOL for Snapshot.
6505
58487
The Paircreate operation failed because
the specified primary data volume was
a Pool-VOL.
6505
58490
Only the pair option of the primary data
volume was updated. Failed to update
the pair option of the secondary data
volume.
6505
58500
The Add Pair (Paircreate) operation
failed because the Continuous Access
Journal or the Continuous Access Journal
Z function of the secondary storage
system does not support external
volumes.
6505
58501
The Paircreate operation failed because
the Continuous Access Journal function
of the secondary storage system does
not support VMA of Data Retention.
6505
58502
The operation failed because the volume
capacity of the secondary storage system
has exceeded the licensed capacity of
Open Systems Array Management.
6505
58503
The specified operation failed due to the
attribute or the mirror status in the
journal.
6505
58504
The operation failed. Please refresh the
window and retry the operation. If this
problem persists, please contact HP
Technical Support.
6505
58508
The Add Pair (Paircreate) operation
failed because the IO suppression mode
of the specified primary data volume was
enabled.
Recommended Action
Confirm the state of the specified primary
data in the Snapshot window.
Check the state of the specified primary
data volume.
Confirm the status of the specified
primary data volume.
A communication error between the
primary and the secondary storage
systems occurred, or the microcode of
the secondary storage system does not
support the change pair option function.
Check the main microcode of the
secondary storage system, and contact
HP Technical Support to confirm whether
the microcode supports the change pair
option function. If the microcode supports
the function, contact HP Technical
Support because a communication error
might have occurred.
Check the DKCMAIN microcode version
of the secondary storage system, and
contact HP Technical Support to confirm
whether the Continuous Access Journal
or the Continuous Access Journal Z
function supports external volumes.
Check the DKCMAIN microcode version
of the secondary storage system, and
contact HP Technical Support to confirm
whether the Continuous Access Journal
function supports Data Retention VMA.
Confirm the licensed capacity of the
Open Systems Array Management of the
secondary storage system. To perform
the specified operation, purchase a
license key that allows you to use a
capacity larger than the current capacity.
Check the attribute and the mirror status
of the journal.
If this problem persists, please contact
HP Technical Support.
Disable the IO suppression mode of the
specified primary data volume on the
Universal Volume Mgr window.
Severity
Level
W
W
W
E
W
W
W
W
W
W
Part code 6505 207