HP XP P9500 Manual: Part Code 00622

Hp p9000 remote web console messages (av400-96401, october 2011).
Hide thumbs

Advertisement

Table 22 Error codes (part code 0605) (continued)
Part
Error
Code
Number
0605
78056
0605
78057
0605
78058
0605
78060

Part code 00622

Table 23 Error codes (part code 00622)
Part
Error
Code
Number
00622
105009
00622
105040
00622
105042
00622
105084
00622
105204
00622
105234
00622
105235
00622
105236
00622
105237
00622
105238
56
Message (part code group 0nnn)
Error Message
contains the external volume that belongs
to a resource group to which the user
has no access right.
The operation cannot be done because
the external volume which belongs to a
resource group to which the user has no
access right uses the specified external
WWN.
The specified LDEV cannot be used
because the user has no access right to
a resource group to which the LDEV
belongs.
The operation cannot be done because
the specified external volume contains
the LDEV that belongs to a resource
group to which the user has no access
right.
The cache mode cannot be changed
because the specified external volume
includes the LDEVs in the pool where
internal and external volumes coexist.
Error Message
All the check boxes are cleared.
[Detail] is clicked without selecting any
row.
[Delete] is clicked without selecting any
row.
The setting cannot be changed, because
an invalid value has been input.
A necessary program product is not
installed, or insufficient permissions to
execute editorial operation.
A radio button is not selected.
The operation cannot be done because
no row is selected.
The operation cannot be executed
because no target item is selected.
External path group creation has not
finished yet.
Failed to allocate a Parity Group ID.
Recommended Action
Verify the resources allocation for the
user with security administrator role.
Verify the resources allocation for the
user with security administrator role.
Verify the resources allocation for the
user with security administrator role.
Release the allocation of the pool in
which internal and external pools coexist
if there is a volume whose cache mode
cannot be changed.
Recommended Action
Check the check boxes for the items that
you want to change, then retry the
operation.
Select one or more table rows.
Select one or more table rows.
Check the setting(s).
Install a necessary program product.
Otherwise, execute the operation with
the user ID who has a permission to
execute editorial operation, or permit the
user to enable the operation.
Check the setting(s).
Select one or more table rows.
Set a target to be operate on the selected
table, then execute the operation.
Create an external path group.
Check the setting(s).
Severity
Level
W
W
W
W
Severity
Level
W
W
W
W
W
W
W
W
W
W

Advertisement