HP XP P9500 Manual Page 190

Hp p9000 remote web console messages (av400-96401, october 2011).
Hide thumbs

Advertisement

Table 56 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
8727
6505
8728
6505
8729
6505
8730
6505
8731
6505
8733
6505
8734
6505
8735
190 Message (part code group 6nnn)
Error Message
The number of minimum paths exceeds
the number of normal paths.
The number of minimum paths exceeds
the number of normal paths.
An internal error occurred.
The specified logical address is incorrect.
The existing logical addresses are not
the same.
Continuous Access Journal or Continuous
Access Journal Z is not installed in the
storage system.
Continuous Access Journal or Continuous
Access Journal Z is not installed in the
remote storage system.
The serial number or the controller ID of
the remote subsystem is incorrect.
Recommended Action
Do either of the following to recover from
the error:
If the error code is 100c, add normal
paths, then set the minimum number
of paths.
If the error code is 100d, add normal
paths, then delete paths. Alternatively,
reduce the minimum number of paths,
then delete paths.
Do either of the following to recover from
the error:
If the error code is 100c, add normal
paths, then set the minimum number
of paths.
If the error code is 100d, add normal
paths, then delete paths. Alternatively,
reduce the minimum number of paths,
then delete paths.
Check the SSB log, then contact HP
Technical Support.
Do either of the following to recover from
the error:
If you are adding DKCs, specify the
same logical address.
If you are editing paths, specify the
same logical address as the existing
paths.
Delete the DKC once, then add the DKC
using the same logical address.
Continuous Access Journal or Continuous
Access Journal Z must be installed in the
storage system when you create a path
or a pair for Continuous Access Journal
or Continuous Access Journal Z. Install
Continuous Access Journal or Continuous
Access Journal Z in the storage system.
Continuous Access Journal or Continuous
Access Journal Z must be installed in the
remote storage system when you create
a path or a pair for Continuous Access
Journal or Continuous Access Journal Z.
Install Continuous Access Journal or
Continuous Access Journal Z in the
remote storage system.
Check the serial number and the
controller ID of this remote storage
system and already registered remote
storage systems, then specify the correct
values.
If the specified values are correct, check
the cable connection of the remote
storage system. If the problem persists,
please contact HP Technical Support.
Severity
Level
W
W
E
W
W
W
W
W

Advertisement