Download Print this page

HP XP P9500 Manual Page 246

Hp p9000 remote web console messages (av400-96401, october 2011).
Hide thumbs

Advertisement

Table 62 Error codes (part code 7005) (continued)
Part
Error
Code
Number
7005
8519
7005
8520
7005
8521
7005
8522
7005
8523
7005
8524
7005
8525
7005
8526
7005
8527
7005
8528
7005
8529
7005
8530
7005
8531
7005
8532
7005
8533
7005
8535
7005
8536
7005
8537
7005
8538
7005
8539
7005
8540
246 Message (part code group 7nnn)
Error Message
Volumes specified as P-VOL and S-VOL,
or those constituting LUSE are not
consistent in capacity.
You cannot set a pair, because the
volume type is different for each.
The number of multiple copy jobs
exceeded the maximum.
The emulation type of the P-VOL is not
supported.
The emulation type of the S-VOL is not
supported.
The emulation type is not supported.
An internal logic error occurred.
An internal logic error occurred.
An internal logic error occurred.
An internal logic error occurred.
An internal logic error occurred.
An internal logic error occurred.
An internal logic error occurred.
The command has been rejected,
because the P-VOL or the S-VOL is being
used by the host.
The command has been rejected,
because the emulation type of the
specified volume is not supported or the
specified S-VOL is used as a data volume
of Continuous Access Journal.
A processor failure was detected.
A cache failure was detected.
The cache capacities do not match.
An SM failure was detected.
There is insufficient shared memory to
create 4096 pairs.
There is sufficient shared memory to
create 4096 pairs, but initial subsystem
setup is required before creating pairs.
Recommended Action
Select volumes with the same capacity.
When specifying LUSE volumes as P-VOL
and S-VOL, the capacity of each volume
constituting the LUSE volumes must be
the same.
Specify the volume of the same emulation
type, and retry the operation.
Check the contents, and retry.
Specify the emulation type supported in
HOMRCF.
Specify the emulation type supported in
HOMRCF.
Specify the emulation type supported in
HOMRCF.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Stop the usage by the host.
Specify a volume of the supported
emulation type. When the S-VOL is used
as a data volume of Continuous Access
Journal, the command cannot be
executed in the current status of
Continuous Access Journal pair.
See the section "Sharing Business Copy
volumes" in the HP P9000 Business Copy
User Guide for the relation between the
status of Continuous Access Journal pair
and the Business Copy operations.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
There is insufficient shared memory in
DKC. Please contact HP Technical
Support.
Please contact HP Technical Support.
Severity
Level
W
W
W
W
W
W
E
E
E
E
E
E
E
W
W
E
E
E
E
E
E

Advertisement

   Also See for HP XP P9500

   Related Manuals for HP XP P9500

Comments to this Manuals

Symbols: 0
Latest comments: