Table 41 Error codes (part code 4005) (continued)
Part
Error
Code
Number
4005
55245
4005
55246
4005
55247
4005
55265
4005
55530
4005
55531
4005
55532
4005
55533
4005
55534
4005
55535
4005
55536
4005
55537
4005
55538
4005
55539
4005
55540
4005
55541
4005
55542
120 Message (part code group 4nnn)
Error Message
The number of cache residency areas set
for the CLPR exceeds the maximum
available number of cache residency
areas.
CLPR No:%s
The total number of Cache Residency
areas set for the CLPRs and the maximum
number of the Cache Residency areas
in the subsystem are not equal.
The cache residency size set for the CLPR
is not a multiple of 512 MB.
CLPR No:%s
The parity group that contains the
volume(s) to which Cache Residency is
set cannot be migrated to another CLPR.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
The specified extent is over the size
which can be specified.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
Cache Residency cannot be set to the
specified volume because the IO
Suppression mode is set to Enable.
Cache Residency cannot be set to this
volume because its cache mode is set to
Disable.
The specified function is not available
because it requires Open System Array
Management.
The specified function is not available
because it requires Mainframe Array
Management.
An error occurred during SVP
processing.
Recommended Action
Check the settings, then retry the
operation.
Check the settings, then retry the
operation.
Check the settings, then retry the
operation.
Remove the Cache Residency settings
from the volumes, and then migrate the
parity group.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Set the extent area within the size which
can be specified, then retry the
operation.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Disable the IO Suppression mode of this
volume, then retry the operation, or
remove the volume from the volumes to
be set.
Enable the cache mode of this volume,
and then retry the operation, or remove
the volume from the volumes to be set.
Install the necessary program product.
Install the required program product.
If this problem persists, please contact
HP Technical Support.
Severity
Level
W
W
W
W
E
E
W
E
E
E
E
E
W
W
E
W
E

Advertisement