Part Code 7007 - HP XP P9500 Manual

Hp p9000 remote web console messages (av400-96401, october 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 62 Error codes (part code 7005) (continued)
Part
Error
Code
Number
7005
75005
7005
75006
7005
75007
7005
75015
7005
78053
7005
78054
7005
78055
7005
78108
7005
78109
7005
781 10

Part code 7007

Table 63 Error codes (part code 7007)
Part
Error
Code
Number
7007
6012
7007
71 1 1
260 Message (part code group 7nnn)
Error Message
The command was rejected, because no
LU path was set to the volume specified
as P-VOL.
The command was rejected, because no
LU path was set to the volume specified
as S-VOL.
The command was rejected, because no
LU path was set to the volume specified
as a reserved VOL.
The specified LDEV cannot be used
because the user has no access right to
a resource group to which the LDEV
belongs.
The operation failed because the current
microcode version does not support the
capacity of specified P-VOL.
The operation failed because the current
microcode version does not support the
capacity of specified S-VOL.
The operation failed because the current
microcode version does not support the
capacity of specified reserved volume.
The command was rejected, because the
pool associated with the Thin
Provisioning volume that is specified as
the S-VOL was being initialized.
The command was rejected, because the
pool associated with the Thin
Provisioning volume that is specified as
the S-VOL was being initialized.
The command was rejected, because the
pool associated with the Thin
Provisioning volume that is specified as
the reserved volume was being
initialized.
Error Message
An error occurred during SVP
processing.
An error occurred during SVP
processing.
Recommended Action
Set an LU path to the specified P-VOL,
then retry the operation.
Set an LU path to the specified P-VOL,
then retry the operation.
Set an LU path to the specified P-VOL,
then retry the operation.
Verify the resources allocation for the
user with security administrator role.
Check the microcode version of the
storage system.
Check the microcode version of the
storage system.
Check the microcode version of the
storage system.
Wait until the initialization of the pool is
completed, and then retry the operation.
Wait until the initialization of the pool is
completed, and then retry the operation.
Wait until the initialization of the pool is
completed, and then retry the operation.
Recommended Action
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Severity
Level
W
W
W
W
W
W
W
W
W
W
Severity
Level
E
E

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9000P9500

Table of Contents