Table 56 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
58609
The timer type cannot be changed,
because the specified journal belongs to
an extended consistency group (EXCTG).
6505
58610
The parameter specified in the extended
consistency group (EXCTG) operation is
invalid.
6505
5861 1
The specified operation failed because
the microcode exchange was in progress
on the subsystem in the extended
consistency group (EXCTG).
6505
58612
The previously executed update
processing of the extended consistency
group (EXCTG) has not completed.
Please wait for a while, and then retry
the operation.
6505
58613
The command device is specified
incorrectly.
6505
58614
The specified Journal cannot be added
to the extended consistency group
(EXCTG), because the journal is not
registered, or the journal is in the Initial
state.
6505
58615
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified mirror ID is not
registered in the specified journal.
6505
58616
The specified journal cannot be added
to extended consistency group (EXCTG).
6505
58617
Journals cannot be added to the
extended consistency group (EXCTG),
because the attributes of the EXCTG and
the journal are different.
6505
58618
Journals cannot be added to the
extended consistency group (EXCTG),
because the timer type of the specified
journal is not "System."
6505
58620
The status of the extended consistency
group (EXCTG) is changing.
6505
58621
Journals cannot be added to the
extended consistency group (EXCTG),
because the attribute of the specified
journal is invalid.
6505
58624
Journals cannot be added to the
extended consistency group (EXCTG),
because the combination of the serial
number and the command device is
invalid.
Recommended Action
Check if the specified journal belongs to
an extended consistency group (EXCTG).
Refresh the window, then retry the
operation. If this problem persists, please
contact HP Technical Support.
Retry the operation after the microcode
exchange completes.
Wait a while, then retry the operation.
Check whether the specified CU number
and the LDEV number indicate a
command device.
Verify the status of the specified journal.
Check the mirror ID of the specified
journal.
Check the state of the journal in the
storage system where the specified
journal belongs to, or the installation
status of the program product.
Check the attributes of the specified
extended consistency group (EXCTG)
and the journal.
Check the timer type of the specified
journal.
Wait for a while, refresh the window,
then retry the operation.
Check the attribute of the specified
journal.
Check if the specified command device
exists in the device of specified serial
number.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
Part code 6505
21 1

Advertisement

COMING SOON