Table 33 Error codes (part code 3005) (continued)
Part
Error
Error Message
Code
Number
3005
78042
The operation cannot be executed
because the pool where the Thin
Provisioning Volume belongs to is now
in pool shrinking or tier relocation
process.
3005
78043
The operation cannot be executed
because the specified pool has
following problems.
3005
78044
The operation cannot be executed
because the specified pool has one of
the following problems.
3005
78045
The operation cannot be executed
because the THP V-VOL of the specified
pool has following problems.
3005
78046
The storage system is in the state that
requires maintenance (for example, the
cache memory is blocked, or some
other factors.)
3005
78047
A sufficient Cache Control Device
cannot be allocated to the target
volume.
3005
78048
The pool shrinking was aborted
because the operation to stop pool
shrinking was executed.
3005
78049
The operation cannot be executed
because the storage system is in the
process of shutting down.
3005
78052
The operation cannot be executed
because the specified pool is in the
process of pool shrinking.
3005
78053
The operation failed because the
specified resource was not installed.
3005
78054
The operation failed because the
specified name was already registered.
3005
78059
A pool volume cannot be set to the
specified pool because the number of
drive types exceeds the supported
number.
The pool usage exceeds the
threshold.
The pool status is invalid.
The status of the specified Pool-VOL
is not normal.
The I/O load of the THP V-VOL
associated with the specified pool
is high.
The THP V-VOL is blocked.
The THP V-VOL is being formatted.
Recommended Action
Wait until the pool is shrunk or the tier
is relocated, or abort it.
Verify the following items, and then retry
the operation.
The threshold value of the pool.
The pool status.
Execute any of the following actions,
then retry the operation.
If this problem persists, please contact
HP Technical Support.
Restore the Pool-VOL to the normal
status.
Reduce the I/O load of the THP
V-VOL.
Check the THP V-VOL status, then retry
the operation.
If this problem persists, please contact
HP Technical Support.
Please contact HP Technical Support.
Delete unnecessary volumes, then retry
the operation. If this problem persists,
please contact HP Technical Support.
Check the pool status.
Power on the storage system, then retry
the operation.
Wait until the pool is shrunk, or stop the
operation.
Check if the specified resource is
installed or not.
Change the name to another one, then
retry the operation.
Check the number of the supported drive
types, then retry the operation.
Severity
Level
W
E
E
E
E
W
W
W
W
W
W
W
Part code 3005