Table 56 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
58595
6505
58596
6505
58597
6505
58600
6505
58601
6505
58602
6505
58603
6505
58604
6505
58605
6505
58606
6505
58607
6505
58608
210
Message (part code group 6nnn)
Error Message
The Paircreate operation failed because
the Continuous Access Journal function
of the secondary subsystem does not
support LUSE volumes.
The operation to change the status to the
status ready for Delta resync failed
because At-Time Split was set to the
specified restore journal.
Journals cannot be added to the
extended consistency group (EXCTG),
because the controller ID of the specified
serial number is invalid.
Journals cannot be added to the
extended consistency group (EXCTG),
because Continuous Access Journal Z or
Continuous Access Journal 3DC & 4x4
Open Mainframe function is not
installed.
Journals cannot be added to the
extended consistency group (EXCTG),
because the additional shared memory
is not installed.
Journals cannot be added to the
extended consistency group (EXCTG),
because the number of storage systems
in the EXCTG exceeds the maximum.
Journals cannot be added to the
extended consistency group (EXCTG),
because the number of journals in the
EXCTG exceeds the maximum.
The specified journal is already
registered in the extended consistency
group (EXCTG).
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified mirror ID is
different from the mirror ID existed in the
EXCTG.
Journals cannot be deleted from the
extended consistency group (EXCTG),
because the specified EXCTG is not
registered.
Journals cannot be deleted from the
extended consistency group (EXCTG),
because the specified journal is not
registered.
The Resume Pair operation failed.
Although the restore journal belongs to
an extended CT group (EXCTG), the
primary storage system does not support
the EXCTG function.
Recommended Action
Confirm that the Continuous Access
Journal function of the secondary storage
system supports LUSE volumes.
Check if the At-Time Split is set to the
specified restore journal with Business
Continuity Manager.
Check the controller ID of the specified
serial number.
Confirm that the Continuous Access
Journal Z and the Continuous Access
Journal 3DC & 4x4 Open Mainframe
function are installed in the storage
system.
Please contact HP Technical Support and
install additional shared memory.
Check the number of storage systems in
the specified extended consistency group
(EXCTG).
Check the number of journals in the
specified extended consistency group
(EXCTG).
Check the number of journals in the
specified extended consistency group
(EXCTG).
Check the mirror ID of the specified
extended consistency group (EXCTG).
Check the status of the specified
extended consistency group (EXCTG).
Check the journals in the specified
extended CT group.
Update the microcode of the primary
storage system to the version which
supports the EXCTG function.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W