Table 53 Error codes (part code 6005) (continued)
Part
Error
Error Message
Code
Number
6005
8779
Continuous Access Synchronous or
External Storage Access Manager is
not supported under the RCU controller
type.
6005
8780
Continuous Access Synchronous Z
function is not installed in the specified
controller.
6005
8781
Continuous Access Synchronous Z
function is not installed in the specified
controller.
6005
8785
The M-VOL is defined as the expansion
volume.
6005
8786
The R-VOL is defined as the expansion
volume.
6005
8788
The specified expanded volume in the
RCU is not defined.
6005
8789
Combination of the M-VOL and R-VOL
configuration is not valid.
6005
8790
The specified expansion volume
(Port/GID/LUN) of the RCU is not
usable.
6005
8791
The specified M-VOL is still online from
another HOST.
6005
8792
The operation failed because the
Volume Retention function was not
installed in the specified RCU.
Install Volume Retention, and retry the
operation.
The operation failed because the
Mainframe Array Management function
was not installed in the specified RCU.
6005
8793
The Continuous Access Synchronous
function is not installed in the specified
controller(s).
6005
8794
The Continuous Access Synchronous
function is not installed in the specified
controller(s).
6005
8795
The operation failed because the
specified M-VOL applied to any of the
following:
A T-VOL of Business Copy Z which
is not in the Split pair (PSUS) status.
An S-VOL of Business Copy which
is not in the Split pair (PSUS) status.
Recommended Action
memory, then retry the
operation.
Confirm the controller type
of the RCU.
Install the Continuous Access
Synchronous Z in the MCU
and the RCU.
Install the Continuous Access
Synchronous Z in the MCU
and the RCU.
Check the volume again.
Check the volume again.
Check the Port, GID and
LUN settings of the RCU.
Verify the configuration of
both the M-VOL and the
R-VOL.
Confirm the status of the
specified expansion volume
and microcode version of
the RCU.
Vary the concerned path
offline from the other host,
then retry the operation.
Install the Volume Retention
in the MCU and the RCU,
then retry the operation.
Install the Mainframe Array
Management in the MCU
and the RCU, then retry the
operation.
Install Continuous Access
Synchronous in the MCU
and the RCU, then retry the
operation.
Install Continuous Access
Synchronous in the MCU
and the RCU, then retry the
operation.
Check the status of the
specified M-VOL from the
host or the SVP.
Severity Level
W
W
W
W
W
W
W
W
W
W
W
W
W
Part code 6005 159