HP XP P9500 Manual page 264

Hp p9000 remote web console messages (av400-96401, october 2011)
Hide thumbs Also See for XP P9500:
Table of Contents

Advertisement

Table 65 Error codes (part code 7105) (continued)
Part
Error
Code
Number
7105
8506
7105
8507
7105
8508
7105
8509
7105
8510
7105
851 1
7105
8512
7105
8513
7105
8514
7105
8515
7105
8516
7105
8517
7105
8518
7105
8519
7105
8520
7105
8521
7105
8522
7105
8523
7105
8524
7105
8525
264 Message (part code group 7nnn)
Error Message
The command has been rejected,
because the specified T-VOL or reserved
volume is used by the host.
The Split Pair command was issued to
the pairs in the split status.
The Add Pair command was issued to
the pairs in the split status.
The Split command with the QUIESCE
specification was issued to a secondary
boot device.
The M-VOL Suspend command was
issued to a secondary boot device.
You cannot reserve the volume, because
a path group is set.
Cannot perform Resync or Suspend
operation because of the path group
setting.
The command has been rejected,
because the specified S-VOL is used by
the host.
No reserved volume can be allocated.
The number of cylinders in the reserved
volume exceeds the maximum.
The number of S-VOL cylinders exceeds
the maximum.
The number of T-VOL cylinders exceeds
the maximum.
You cannot create a pair, because the
track format is different for each.
You cannot set a pair because the
number of cylinders is different for each.
Make sure that the capacity is the same
for both.
You cannot set a pair, because the
volume type is different for each.
The number of multiple copy jobs
exceeded the maximum.
The emulation type of the S-VOL is not
supported.
The emulation type of the T-VOL is not
supported.
The emulation type is not supported.
An internal logic error occurred.
Recommended Action
pairs and the commands that can be
accepted.
Vary the T-VOL or the reserved volume
offline from the mainframe host, then
issue the command again.
You cannot execute the Split Pair
operation because the pair is already in
the split status.
You cannot execute the Add Pair
operation to the pairs in the split status.
Check the contents, and then retry.
Check the contents, and then retry.
Detach the S-VOL from the host, or delete
the Remote Copy path.
Detach the S-VOL from the host, or delete
the Remote Copy path.
Vary the S-VOL offline from the
mainframe host, then issue the command
again.
Delete the Reserve volume.
Check the contents, and retry.
Check the contents, and retry.
Check the contents, and retry.
Check the emulation type.
Check the volume capacity.
Specify the volume with the same
emulation type, and retry the operation.
Check the contents, and retry.
Specify the supported emulation type.
Specify the supported emulation type.
Specify the supported emulation type.
Please contact HP Technical Support.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
E