Module Requirements

For information about the modules that support POS interfaces on ERX14xx models,
ERX7xx models, and the ERX310 router:
For information about the modules that support POS interfaces on the E120 and
E320 routers:

Interface Specifiers

The configuration task examples in this chapter use the slot/port[.subinterface ] format
to specify a POS interface. However, the interface specifier format that you use
depends on the router that you are using.
For ERX7xx models, ERX14xx models, and ERX310 router, use the
slot/port[.subinterface ] format. For example, the following command specifies a POS
interface on slot 0, port 1 of an ERX7xx model, ERX14xx model, or ERX310 router.
For E120 and E320 routers, use the slot/adapter/port format, which includes an
identifier for the bay in which the I/O adapter (IOA) resides. In the software, adapter
0 identifies the right IOA bay (E120 router) and the upper IOA bay (E320 router);
adapter 1 identifies the left IOA bay (E120 router) and the lower IOA bay (E320
router). For example, the following command specifies a POS interface on slot 5,
adapter 0, port 0 of an E320 router.
For more information about supported interface types and specifiers on E Series
routers, see Interface Types and Specifiers in JUNOSe Command Reference Guide.

References

For more information about POS interfaces, consult the following resources:
ERX705 router
ERX310 router
See ERX Module Guide, Table 1, Module Combinations for detailed module
specifications.
See ERX Module Guide, Appendix A, Module Protocol Support for information about
the modules that support POS.
See E120 and E320 Module Guide, Table 1, Modules and IOAs for detailed module
specifications.
See E120 and E320 Module Guide, Appendix A, IOA Protocol Support for information
about the modules that support POS.
host1(config)#interface pos 0/1
host1(config)#interface pos 5/0/0
RFC 1662 PPP in HDLC-like Framing (July 1994)