To specify a nondefault time interval in the range 5–30 seconds (for ATM VCs)
or 5–300 seconds (for ATM VPs) at which the router calculates bit rate and packet
rate statistics, use the optional load-interval keyword. The default time interval
for either command is 5 seconds.
To display the time at which the router calculates bit rate and packet rate statistics
for the current interval, use the optional display-time-of-day keyword.
To stop either command, press Ctrl+c.
Field descriptions
Interface Interface identifier for the ATM interface on which the VC or VP
resides
VCD Virtual circuit descriptor that identifies the VC (monitor atm vc
command only)
VPI Virtual path identifier of the PVC (monitor atm vp command only)
Seconds between polls Number of seconds at which the router calculates
bit rate and packet rate statistics
Input bps/pps Number of bits per second (bps) and packets per second
(pps) received on this interface during the specified load interval
Output bps/pps Number of bits per second (bps) and packets per second
(pps) transmitted on this interface during the specified load interval
Time Time of day, in hh:mm:ss format, at which the router calculates the
bit rate and packet rate statistics for the current interval
Example 1 Displays bit rate and packet rate statistics over the default (5-second)
load interval for a single ATM VC
host1#monitor atm vc atm 12/0 100
Interface
VCD
------------------ ----- -------- --------------- ---------------
ATM 12/0
ATM 12/0
ATM 12/0
ATM 12/0
ATM 12/0
ATM 12/0
host1#^C
Example 2 Displays bit rate and packet rate statistics over the default (5-second)
load interval for two ATM VCs, with the time of day that the statistics were
calculated
host1#monitor atm vc atm 12/0 100 atm 12/0 200 display-time-of-day
Interface
VCD
------------------ ----- -------- --------------- --------------- --------
ATM 12/0
ATM 12/0
ATM 12/0
Seconds
between
polls
Input bps/pps
100
0
--/--
100
5
6631624/6476
100
5
6630808/6475
100
5
6632448/6477
100
5
6629168/6473
100
5
6631008/6475
Seconds
between
polls
Input bps/pps
100
0
--/--
200
0
--/--
100
5
6635104/6479
Chapter 1: Configuring ATM
Output bps/pps
--/--
6631624/6476
6631008/6475
6632240/6476
6629168/6473
6631216/6475
Time
Output bps/pps
(UTC)
--/-- 17:33:06
--/-- 17:33:06
6635104/6479 17:33:11