H2: Mfdo - YASKAWA GA800 Technical Reference

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

11.10 H: Terminal Functions
Setting Value
Function
176
!Down 2 Command
177
!ASR Gain (C5-03)
Select
178
!Analog TorqueRef
Polarity Invert
17E
!Reverse Rotation
Identifier
17F
!PID Bi-Directional
Enable
19F
!DWEZ Disable

H2: MFDO

No.
Name
(Hex.)
H2-01
Term M1-M2 Function
Selection
(040B)
H2-02
Term M3-M4 Function
Selection
(040C)
H2-03
Term M5-M6 Function
Selection
(040D)
H2-06
Watt Hour Output Unit
Selection
(0437)
H2-07
Modbus Register 1
Address Select
(0B3A)
H2-08
Modbus Register 1 Bit
Select
(0B3B)
594
V/f
CL-V/f
OLV
CLV
AOLV
When the terminal deactivates, the motor decelerates by decreasing the frequency reference bias value. Set !Up 2
Command and !Down 2 Command together.
Note:
When you use the functions, set the optimal bias limit values with d4-08 and d4-09 [Up/Down 2 Bias Upper Limit/
Lower Limit (Up/Down 2)].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to switch the ASR proportional gain to C5-01 [ASR Proportional Gain 1] or C5-03 [ASR
Proportional Gain 2].
ON : C5-01
OFF : C5-03
V/f
CL-V/f
OLV
CLV
AOLV
Switches the rotation direction of the external torque reference.
ON : External torque reference forward direction
OFF : External torque reference reverse direction
V/f
CL-V/f
OLV
CLV
AOLV
Lets you set the rotation direction of the motor when F1-21, F1-37 = 0 [Encoder Option Function Selection = A pulse
detection] for Simple Closed Loop V/f Control method and Closed Loop V/f Control method.
ON : Forward run
OFF : Reverse run
V/f
CL-V/f
OLV
CLV
AOLV
Switches the PID Bi-Directional output to enable or disable.
ON : Disable
OFF : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Switches the DriveWorksEZ program saved in the drive to enable or disable.
ON : Enabled
OFF : Disable
Note:
Set A1-07 = 2 [DriveWorksEZ Function Selection = Digital input] to use this function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDO terminal M1-M2.
Note:
When you do not use the terminal or when you use the terminal in through mode, set
this parameter to F.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDO terminal M3-M4.
Note:
When you do not use the terminal or when you use the terminal in through mode, set
this parameter to F.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for MFDO terminal M5-M6.
Note:
When you do not use the terminal or when you use the terminal in through mode, set
this parameter to F.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the unit for the output signal when H2-01 to H2-03 = 39 [MFDO Function Selection
= Watt Hour Pulse Output].
0 : 0.1 kWh units
1 : 1 kWh units
2 : 10 kWh units
3 : 100 kWh units
4 : 1000 kWh units
V/f
CL-V/f
OLV
CLV
AOLV
Sets the address of the MEMOBUS/Modbus register output to the MFDO terminal.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bit of the MEMOBUS/Modbus register output to the MFDO terminal.
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Ref.
904
904
904
904
904
904
Default
Ref.
(Range)
0
907
(0 - 1FF)
1
907
(0 - 1FF)
2
907
(0 - 1FF)
0
907
(0 - 4)
0001
908
(0001 - 1FFF)
0000
908
(0000 - FFFF)

Advertisement