Setting Value
Function
40
Forward RUN (2-Wire)
41
Reverse RUN (2-Wire)
42
Run Command (2-Wire
Sequence 2)
43
FWD/REV (2-Wire
Sequence 2)
44
Add Offset Frequency 1
(d7-01)
45
Add Offset Frequency 2
(d7-02)
46
Add Offset Frequency 3
(d7-03)
47
Node Setup (CANopen)
60
DC Injection Braking
Command
61
Speed Search from Fmax
62
Speed Search from Fref
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Forward Run command for 2-wire sequence 1. Set this function and H1-xx = 41 [Reverse RUN (2-Wire)]
together.
ON : Forward Run
OFF : Stop
Note:
• If you turn ON the Forward Run command terminal and the Reverse Run command terminal, it will cause an EF
[FWD/REV Run Command Input Error] alarm and the motor will ramp to stop.
• Initialize the drive with a 2-wire sequence to set the Forward Run command to terminal S1.
• This function will not operate at the same time as H1-xx = 42, 43 [Run Command (2-Wire Sequence 2), FWD/
REV (2-Wire Sequence 2)].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Forward Run command for 2-wire sequence 1. Set this function and H1-xx = 40 [Forward RUN (2-Wire)]
together.
ON : Reverse Run
OFF : Stop
Note:
• If you turn ON the Forward Run command terminal and the Reverse Run command terminal, it will cause an EF
[FWD/REV Run Command Input Error] alarm and the motor will ramp to stop.
• Initialize the drive with a 2-wire sequence to set the Reverse Run command to terminal S2.
• This function will not operate at the same time as H1-xx = 42, 43 [Run Command (2-Wire Sequence 2), FWD/
REV (2-Wire Sequence 2)].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Run command for 2-wire sequence 2. Set this function and H1-xx = 43 [FWD/REV (2-Wire Sequence 2)]
together.
ON : Run
OFF : Stop
Note:
This function will not operate at the same time as H1-xx = 40, 41 [Forward RUN (2-Wire), Reverse RUN (2-
Wire)].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation for 2-wire sequence 2. Set this function and H1-xx = 42 [Run Command (2-Wire
Sequence 2)] together.
ON : Reverse Run
OFF : Forward Run
Note:
• You must input the Run command to rotate the motor.
• This function will not operate at the same time as H1-xx = 40, 41 [Forward RUN (2-Wire), Reverse RUN (2-
Wire)].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-01 [Offset Frequency 1] to the frequency reference when the
terminal activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-02 [Offset Frequency 2] to the frequency reference when the
terminal activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to add the offset frequency set in d7-03 [Offset Frequency 3] to the frequency reference when the
terminal activates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function in CANopen communications to start the Node Setup function to set the drive node address from the
host controller.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the command to use DC Injection Braking to stop the motor.
Note:
When A1-02 = 8 [Control Method Selection = EZOLV], this function is available with a PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to use an external reference to start speed search although b3-01 = 0 [Speed Search Selection at Start
= Disabled] to not allow speed search at start.
Note:
The drive will detect oPE03 [Multi-Function Input Setting Err] when H1-xx = 61 [Speed Search from Fmax] and
H1-xx = 62 [Speed Search from Fref] are set at the same time.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to use an external reference to start speed search although b3-01 = 0 [Speed Search Selection at Start
= Disabled] to not allow speed search at start.
Note:
The drive will detect oPE03 [Multi-Function Input Setting Err] when H1-xx = 61 [Speed Search from Fmax] and
H1-xx = 62 [Speed Search from Fref] are set at the same time.
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.10 H: Terminal Functions
Ref.
897
897
897
897
898
898
898
898
898
899
899
11
589

Advertisement

Table of Contents
loading

Table of Contents