YASKAWA GA800 Technical Reference page 541

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

No.
Name
(Hex.)
A2-28
User Parameter 28
(0121)
A2-29
User Parameter 29
(0122)
A2-30
User Parameter 30
(0123)
A2-31
User Parameter 31
(0124)
A2-32
User Parameter 32
(0125)
A2-33
User Parameter Auto
Selection
(0126)
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 28 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User
Parameter Auto Selection = Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 29 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User
Parameter Auto Selection = Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 30 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User
Parameter Auto Selection = Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 31 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User
Parameter Auto Selection = Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 32 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32. You can set A2-17 to A2-32 when A2-33 = 0 [User
Parameter Auto Selection = Disabled: Manual Entry Required].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the automatic save feature for changes to parameters A2-17 to A2-32 [User
Parameters 17 to 32].
0 : Disabled: Manual Entry Required
1 : Enabled: Auto Save Recent Parms
11.4 A: Initialization Parameters
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
-
715
(Determined by A1-06)
-
715
(Determined by A1-06)
-
715
(Determined by A1-06)
-
715
(Determined by A1-06)
-
715
(Determined by A1-06)
Determined by A1-06
715
(0, 1)
541
11

Advertisement

Table of Contents
loading

Table of Contents