E9: Motor Setting - YASKAWA GA800 Technical Reference

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

E9: Motor Setting

No.
Name
(Hex.)
E9-01
Motor Type Selection
(11E4)
E9-02
Maximum Speed
(11E5)
E9-03
Rated Speed
(11E6)
E9-04
Base Frequency
(11E7)
E9-05
Motor Rated Voltage
(11E8)
E9-06
Motor Rated Current
(FLA)
(11E9)
E9-07
Motor Rated Power
(11EA)
E9-08
Motor Pole Count
(11EB)
E9-09
Motor Rated Slip
(11EC)
E9-10
Motor Line-to-Line
Resistance
(11ED)
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of motor.
0 : Induction (IM)
1 : Permanent Magnet (PM)
2 : Synchronous Reluctance (SynRM)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum speed of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated rotation speed of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated frequency of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated voltage of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated current in amps.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated output in the units from o1-58 [Motor Power Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated slip.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the line-to-line resistance for the motor stator windings.
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.8 E: Motor Parameters
Default
Ref.
(Range)
0
836
(0 - 2)
Determined by E9-01
836
(40.0 - 120.0 Hz)
Determined by E9-01
836
(100 - 7200 min
-1
)
Determined by E9-01
836
(40.0 - 120.0 Hz)
200 V Class: 230.0 V,
837
400 V Class: 460.0 V
(200 V Class: 0.0 - 255.0
V, 400 V Class: 0.0 -
510.0 V)
Determined by E9-01 and
837
o2-04
(10% to 200% of the
drive rated current)
Determined by E9-02 and
837
o2-04
(0.00 - 650.00 kW)
4
837
(2 to 120)
0.000 Hz
837
(0.000 - 20.000 Hz)
Determined by o2-04
838
(0.000 - 65.000 Ω)