C1-01: Acceleration Time 1
No.
Name
(Hex.)
C1-01
Acceleration Time 1
(0200)
RUN
Note:
When C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)], the setting range is 0.00 to 600.00 s.
C1-02: Deceleration Time 1
No.
Name
(Hex.)
C1-02
Deceleration Time 1
(0201)
RUN
Note:
When C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)], the setting range is 0.00 to 600.00 s.
C1-03: Acceleration Time 2
No.
Name
(Hex.)
C1-03
Acceleration Time 2
(0202)
RUN
Note:
When C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)], the setting range is 0.00 to 600.00 s.
C1-04: Deceleration Time 2
No.
Name
(Hex.)
C1-04
Deceleration Time 2
(0203)
RUN
Note:
When C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)], the setting range is 0.00 to 600.00 s.
C1-05: Acceleration Time 3
No.
Name
(Hex.)
C1-05
Acceleration Time 3
(0204)
RUN
Note:
When C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)], the setting range is 0.00 to 600.00 s.
C1-06: Deceleration Time 3
No.
Name
(Hex.)
C1-06
Deceleration Time 3
(0205)
RUN
Note:
When C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)], the setting range is 0.00 to 600.00 s.
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time to accelerate from zero to maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time to decelerate from maximum output frequency to zero.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time to accelerate from zero to maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time to decelerate from maximum output frequency to zero.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time to accelerate from zero to maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time to decelerate from maximum output frequency to zero.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.4 C: Tuning
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
Default
(Range)
10.0 s
(0.0 - 6000.0 s)
12