• A1-07 [DriveWorksEZ Function Selection]
• A2-01 to A2-32 [User Parameter 1 to 32]
To lock parameter settings after making changes without changing the password, enter the incorrect password in A1-
04 and push
.
Enter the Password to Unlock Parameters
Use this procedure to unlock parameter settings.
Set the password in A1-05 [Password Setting], and show the Parameter Setting Mode screen on the keypad.
This procedure verifies the password, and makes sure that the parameter settings are unlocked.
1.
Push
or
2.
Push
or
You can now change parameter settings.
3.
Push
or
4.
Push
to confirm the password.
The drive unlocks the parameters and automatically shows the Parameters Screen.
5.
Push
or
The keypad shows the setting value for [A1-02].
6.
Push
or
Push
(Back) until the keypad shows the Parameter Setup Mode screen.
A1-05: Password Setting
No.
Name
(Hex.)
A1-05
Password Setting
(0105)
This parameter can lock these parameter settings:
• A1-01 [Access Level Selection]
• A1-02 [Control Method Selection]
• A1-03 [Initialize Parameters]
• A1-06 [Application Preset]
• A1-07 [DriveWorksEZ Function Selection]
• A2-01 to A2-32 [User Parameter 1 to 32]
Note:
• Usually, the keypad will not show A1-05. To show and set A1-05, show A1-04 [Password] and then push
the same time.
• After you set A1-05, the keypad will not show it again until you enter the correct password in A1-04. Make sure that you remember the A1-
05 setting value. If you do not know the A1-05 setting value, contact Yaskawa or your nearest sales representative.
• When A1-03 = 2220, 3330 [2-Wire Initialization, 3-Wire Initialization], the drive is initialized to A1-05 = 0000. Be sure to set the password
again when a password is necessary for the application.
• Change the setting value in A1-05 to change the password. The new setting value becomes the new password.
• When you use the password to unlock and change a parameter, enter a value other than the password in A1-04 to lock the parameter again
with the same password.
• If A1-04 ≠ A1-05, MEMOBUS Communication cannot read or write A1-05.
A1-06: Application Preset
WARNING! Sudden Movement Hazard. Check the I/O signals and the external sequences for the drive before you set the
Application Preset function. When you set the Application Preset function (A1-06 ≠ 0), it changes the I/O terminal functions for the
drive and it can cause equipment to operate unusually. This can cause serious injury or death.
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
to select "A: Initialization Parameters", then push
to select [A1-04], then push
to move the digit and enter the password.
to show [A1-02], then push
to make sure that you can change the setting value.
V/f
CL-V/f
OLV
CLV
Set the password to lock parameters and prevent changes to parameter settings. Enter the correct
password in A1-04 [Password] to unlock parameters and accept changes.
.
.
.
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.2 A: Initialization Parameters
Default
(Range)
0000
(0000 - 9999)
and
on the keypad at
12
701