12.11 o: Keypad-Related Settings
o1-50: Trend Plot 2 Scale Maximum Value
No.
Name
(Hex.)
o1-50
Trend Plot 2 Scale
Maximum Value
(11CA)
RUN
Note:
Parameter o1-49 [Trend Plot 2 Scale Minimum Value] sets the lower limit. The lower limit is (o1-49 + 0.1)%.
o1-51: Trend Plot Time Scale Setting
No.
Name
(Hex.)
o1-51
Trend Plot Time Scale
Setting
(11CB)
RUN
o1-55: Analog Gauge Area Selection
No.
Name
(Hex.)
o1-55
Analog Gauge Area
Selection
(11EE)
RUN
0 : +/- Area ( - o1-56 ~ o1-56 )
1 : + Area ( 0 ~ o1-56 )
o1-56: Analog Gauge Area Setting
No.
Name
(Hex.)
o1-56
Analog Gauge Area Setting
(11EF)
RUN
o1-58: Motor Power Unit Selection
No.
Name
(Hex.)
o1-58
Motor Power Unit Selection
(3125)
The drive shows these parameter values in the set units:
• E2-11 [Motor Rated Power]
• E4-11 [Motor 2 Rated Power]
• E5-02 [PM Motor Rated Power]
• E9-07 [Motor Rated Power]
• T1-02 [Motor Rated Power]
• T2-04 [PM Motor Rated Power]
• T4-08 [Motor Rated Capacity]
0 : kW
Shows the motor output in kW units.
1 : HP
Shows the motor output in HP units.
Note:
When you use an LED keypad, use o1-58 to make sure that the units for the monitors and parameters are correct.
1042
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum value for the vertical axis used to display the monitor that was set in o1-25
[Custom Monitor 2] as a trend plot. This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time scale (horizontal axis) to display the trend plot. When you change this setting, the drive
automatically adjusts the data sampling time. This parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the range used to display the monitor set in o1-24 [Custom Monitor 1] as an analog gauge. This
parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the value used to display the monitor set in o1-24 [Custom Monitor 1] as an analog meter. This
parameter is only available with an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the setting unit for parameters that set the motor rated power.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Default
(Range)
100.0%
(-299.9 - +300.0%)
Default
(Range)
300 s
(1 - 3600 s)
Default
(Range)
1
( 0, 1 )
Default
(Range)
100.0%
(0.0 - 100.0%)
Default
(Range)
1
(0, 1)