Item
1000 m (3281 ft) Maximum
Note:
Derate the output current by 1% for each 100 m (328 ft) to install the drive in altitudes between 1000 m to 4000 m (3281 ft to 13123 ft).
Altitude
It is not necessary to derate the rated voltage in these conditions:
• When you install the drive at 2000 m (6562 ft) or lower
• When you install the drive between 2000 m to 4000 m (6562 ft to 13123 ft) and ground the neutral point on the power supply.
Contact Yaskawa or your nearest sales representative if you will not ground the neutral point.
• 10 Hz to 20 Hz: 1 G (9.8 m/s
• 20 Hz to 55 Hz:
Vibration
2004 to 2211, 4002 to 4168, T103 to T168: 0.6 G (5.9 m/s
2257 to 2415, 4208 to 4720, T208 to T720: 0.2 G (2.0 m/s
Installation
Install the drive vertically for sufficient airflow to cool the drive.
Orientation
Item
• UL61800-5-1
• EN61800-3
Harmonized Standard
• IEC/EN61800-5-1
• Two Safe Disable inputs and one EDM output according to EN ISO 13849-1:2015 (PL e (Cat.III)), IEC/EN61508 SIL3
IP00/IP20/UL Open Type
IP20/UL Type 1
Enclosure Protection
IP55/UL Type 12
Design
Note:
To change an IP00/IP20/UL Open Type drive to an IP20/UL Type 1 drive, install a UL Type 1 kit. You cannot install a UL Type 1 kit to models T103 to
T720.