• L2-06
• L2-07
When one of those parameters is set to a value between 600.1 s and 1000.0 s, you can set C1-10 = 0, but the time will
change to 600.00 s.
1 : 0.1 s (0.0 to 6000.0 s)
Sets acceleration and deceleration times in 0.1 s units. The setting range is 0.0 to 6000.0 s.
C1-11: Accel/Decel Time Switchover Freq
No.
Name
(Hex.)
C1-11
Accel/Decel Time Switching
Frequency
(020A)
When the output frequency is at the C1-11 value, the drive automatically switches the acceleration and deceleration
times. Set this parameter to 0.0 to disable this function.
Table 12.31
lists the possible combinations of acceleration and deceleration time switchover frequencies and the
acceleration times for the Motor 2 Selection function.
Table 12.31 Motor and Acceleration and Deceleration Time Combination
C1-11
Less than the setting value
C1-07 [Acceleration Time 4]
Equal to or more than the setting
C1-01 [Acceleration Time 1]
value
C1-14: Accel/Decel Rate Frequency
No.
Name
(Hex.)
C1-14
Accel/Decel Rate Frequency
(0264)
RUN
The acceleration and deceleration rates set in C1-01 to C1-09 [Acceleration/Deceleration Times 1 to 4, Fast Stop
Time] will change when the value of C1-14 changes.
• When C1-14 = 0.0 Hz
– C1-01, C1-03, C1-05, C1-07 [Acceleration Times 1 to 4]: Time to accelerate from 0 Hz to E1-04 [Maximum
Output Frequency]
– C1-02, C1-04, C1-06, C1-08 [Deceleration Times 1 to 4], C1-09 [Fast Stop Time]: Time to decelerate from E1-
04 to 0 Hz.
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
V/f
CL-V/f
OLV
CLV
Sets the frequency at which the drive will automatically change acceleration and deceleration times.
Figure 12.46 Accel/Decel Time Switchover Freq
Motor 1
Acceleration Time
Deceleration Time
C1-08 [Deceleration Time 4]
C1-02 [Deceleration Time 1]
V/f
CL-V/f
OLV
CLV
Sets the base frequency used to calculate acceleration and deceleration rates.
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Acceleration Time
C1-07 [Acceleration Time 4]
C1-05 [Acceleration Time 3]
Description
AOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.4 C: Tuning
Default
(Range)
Determined by A1-02
(0.0 - 590.0 Hz)
Motor 2
Deceleration Time
C1-08 [Deceleration Time 4]
C1-06 [Deceleration Time 3]
Default
(Range)
0.0 Hz
(0.0 - 590.0 Hz)