A2: User Parameters - YASKAWA GA800 Technical Reference

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

No.
Name
(Hex.)
A1-07
DriveWorksEZ Function
Selection
(0128)
A1-11
Firmware Update Lock
(111D)
Expert
A1-12
Bluetooth ID
(1564)

A2: User Parameters

No.
Name
(Hex.)
A2-01
User Parameter 1
(0106)
A2-02
User Parameter 2
(0107)
A2-03
User Parameter 3
(0108)
A2-04
User Parameter 4
(0109)
A2-05
User Parameter 5
(010A)
A2-06
User Parameter 6
(010B)
A2-07
User Parameter 7
(010C)
A2-08
User Parameter 8
(010D)
A2-09
User Parameter 9
(010E)
A2-10
User Parameter 10
(010F)
A2-11
User Parameter 11
(0110)
A2-12
User Parameter 12
(0111)
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to operate with DriveWorksEZ.
0 : DWEZ Disabled
1 : DWEZ Enabled
2 : Enabled/Disabled wDigital Input
V/f
CL-V/f
OLV
CLV
AOLV
Protects the drive firmware. When you enable the protection, you cannot update the drive
firmware.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the password necessary to use Bluetooth to control the drive with a smartphone or
tablet.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 1 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 2 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 3 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 4 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 5 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 6 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 7 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 8 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 9 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 10 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 11 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the parameter number to be shown for number 12 of the [User Custom Parameters]
under the main menu. You can select a maximum of 32 parameters for the drive and set
them to parameters A2-01 to A2-32.
11.4 A: Initialization Parameters
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
0
714
(0 - 2)
0
714
(0, 1)
-
715
(0000 - 9999)
Default
Ref.
(Range)
A1-02
715
(Determined by A1-06)
b1-01
715
(Determined by A1-06)
b1-02
715
(Determined by A1-06)
b1-03
715
(Determined by A1-06)
C1-01
715
(Determined by A1-06)
C1-02
715
(Determined by A1-06)
C6-01
715
(Determined by A1-06)
C6-02
715
(Determined by A1-06)
d1-01
715
(Determined by A1-06)
d1-02
715
(Determined by A1-06)
d1-03
715
(Determined by A1-06)
d1-04
715
(Determined by A1-06)
539