12.8 H: Terminal Functions
3F: PID Feedback High
Setting Value
Function
3F
PID Feedback High
The drive detects FbH [Excessive PID Feedback] when the PID feedback value > b5-36 [PID High Feedback
Detection Lvl] for longer than b5-37 [PID High Feedback Detection Time].
Note:
Refer to
PID Feedback Loss Detection on page 747
4A: During KEB Ride-Thru
Setting Value
Function
4A
During KEB Ride-Thru
Note:
Refer to
KEB Ride-Thru Function on page 964
4B: During Short Circuit Braking
Setting Value
Function
4B
During Short Circuit Braking
Note:
• When A1-02 = 8 [Control Method Selection = EZOLV], this function is available only when you use a PM motor.
• Refer to
b2: DC Injection Braking and Short Circuit Braking on page 729
4C: During Fast Stop
Setting Value
Function
4C
During Fast Stop
4D: oH Pre-Alarm Time Limit
Setting Value
Function
4D
oH Pre-Alarm Time Limit
Note:
Refer to "L8-03: Overheat Pre-Alarm Ope Selection" for more information about drive derating operation.
4E: Braking Transistor Fault (rr)
Setting Value
Function
4E
Braking Transistor Fault (rr)
4F: Braking Resistor Overheat (rH)
Setting Value
Function
4F
Braking Resistor Overheat
(rH)
The braking resistor overheats when the deceleration time is short and there is too much motor regeneration energy.
926
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the drive detects FbH [Excessive PID Feedback].
for more information.
V/f
CL-V/f
OLV
CLV
AOLV
The activates during KEB Ride-Thru.
for more information.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates during Short Circuit Braking.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the fast stop is in operation.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when L8-03 = 4 [Overheat Pre-Alarm Selection = Operate at Reduced Speed (L8-19)] and oH [Heatsink
Overheat] does not clear after the drive decreases the frequency for 10 cycles.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the internal braking transistor overheats and the drive detects an rr [Dynamic Braking Transistor Fault]
fault.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activates when the braking resistor overheats and the drive detects an rH [Braking Resistor Overheat] fault.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
for more information.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061737D GA800 Drive Technical Reference

Advertisement

Table of Contents
loading

Table of Contents