YASKAWA GA800 Technical Reference page 670

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

11.20 Parameters Changed by E1-03 [V/f Pattern Selection]
Table 11.2 Parameters Changed by E1-03: 2030 to 2211 (HD), 2021 to 2169 (ND), 4018 to 4103 (HD), 4012 to 4089 (ND), and
No.
E1-03
Unit
-
0
1
2
3
4
5
6
7
Setting Value
8
9
A
B
C
D
E
F
OLV (2)
CLV (3)
Control Method
Selection
OLV/PM (5)
(A1-02 Setting)
AOLV/PM (6)
CLV/PM (7)
*1
This is the value for 200 V class drives. Double the value for 400 V class drives.
*2
These values are the default settings for E1-04 to E1-10 and E3-04 to E3-10 [V/f Pattern for Motor 2]. These settings are the same as
those for the V/f pattern when E1-03 = 1 [Const Trq, 60Hz base, 60Hz max].
*3
The default setting varies depending on the setting of E5-01 [PM Motor Code Selection].
670
T103 (HD)
E1-04
E1-05
*1
Hz
V
50.0
230.0
60.0
230.0
60.0
230.0
72.0
230.0
50.0
230.0
50.0
230.0
60.0
230.0
60.0
230.0
50.0
230.0
50.0
230.0
60.0
230.0
60.0
230.0
90.0
230.0
120.0
230.0
180.0
230.0
*2
*2
60.0
230.0
60.0
230.0
60.0
230.0
*3
*3
*3
*3
*3
*3
E1-06
E1-07
Hz
Hz
50.0
2.5
60.0
3.0
50.0
3.0
60.0
3.0
50.0
25.0
50.0
25.0
60.0
30.0
60.0
30.0
50.0
2.5
50.0
2.5
60.0
3.0
60.0
3.0
60.0
3.0
60.0
3.0
60.0
3.0
*2
*2
60.0
3.0
60.0
3.0
60.0
0.0
*3
-
*3
-
*3
-
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
E1-08
*1
E1-09
V
Hz
16.1
1.3
16.1
1.5
16.1
1.5
16.1
1.5
40.3
1.3
57.5
1.3
40.3
1.5
57.5
1.5
20.7
1.3
26.5
1.3
20.7
1.5
26.5
1.5
16.1
1.5
16.1
1.5
16.1
1.5
*2
*2
16.1
1.5
12.7
0.5
0.0
0.0
*3
-
*3
-
-
0.0
E1-10
*1
V
8.1
8.1
8.1
8.1
6.9
8.1
6.9
8.1
10.4
12.7
10.4
15.0
8.1
8.1
8.1
*2
8.1
2.3
0.0
-
-
-

Advertisement

Table of Contents
loading

Table of Contents