YASKAWA GA800 Technical Reference page 376

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

7.4 Fault
Code
Name
oFA40
CtrlResSel 1Err
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA41
Drive Receive Time Over 4
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA42
CtrlResSel 2Err
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFA43
Drive Receive Time Over 5
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFb00
Option Not Compatible with Port
Note:
• Do a Fault Reset to clear the fault.
• Fault trace is not available for these faults.
Code
Name
oFb01
Option Fault/Connection Error
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFb02
Duplicate Options
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFb03
Diagnostic Error
Note:
Do a Fault Reset to clear the fault.
Code
Name
oFb04
Flash Write Mode
Note:
Do a Fault Reset to clear the fault.
376
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Causes
The option connected to connector CN5-B is not
compatible.
Causes
The option card connected to connector CN5-B was
changed during operation.
Causes
The same option cards or the same type of option
cards are connected to connectors CN5-A, B, and C.
Causes
A fault occurred in the option card.
Causes
A fault occurred in the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
Connect the option to the correct connector.
Note:
DO-A3, AO-A3, PG-B3, and PG-X3 options can connect to
connector CN5-B. To connect only one PG option card, use the
CN5-C connector.
Possible Solutions
1.
De-energize the drive.
2.
Refer to the option card manual and correctly connect the
option card to the connector on the drive.
Possible Solutions
Connect the option card to the correct connector.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
Possible Solutions
1.
De-energize the drive.
2.
Make sure that the option card is correctly connected to the
connector.
3.
If the problem continues, replace the option card.
YASKAWA SIEPC71061737D GA800 Drive Technical Reference