Setting Value
Function
139
!Watt Hour Pulse Output
13C
!LOCAL Control
Selected
13D
!During Speed Search
13E
!PID Feedback Low
13F
!PID Feedback High
14A
!During KEB Ride-Thru
14B
!During Short Circuit
Braking
14C
!During Fast Stop
14D
!oH Pre-Alarm Reduction
Limit
14E
!Braking Transistor Fault
(rr)
14F
!Braking Resistor
Overheat (rH)
160
!Internal Cooling Fan
Failure
161
!RotorPositionDetection
Complete
162
!Modbus Reg 1 Status
Satisfied
163
!Modbus Reg 2 Status
Satisfied
165
!Standby Output
166
!Comparator 1
167
!Comparator 2
169
!External Power 24V
Supply
16A
!Data Logger Error
190
!DWEZ Digital Output 1
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
V/f
CL-V/f
OLV
CLV
AOLV
Outputs the pulse that shows the watt hours.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the Run command source or frequency reference source is LOCAL.
ON : REMOTE
OFF : LOCAL
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive does speed search.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects FbL [PID Feedback Loss].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects FbH [Excessive PID Feedback].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive executes the KEB Ride-Thru function.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates during Short Circuit Braking.
Note:
When A1-02 = 8 [Control Method Selection = EZ Vector Control], this function is available when you use a PM
motor.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the fast stop is in operation.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when L8-03 = 4 [Overheat Pre-Alarm Selection = Operate at Reduced Speed (L8-19)] and
oH [Heatsink Overheat] does not clear after the drive decreases the frequency for 10 cycles.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the internal braking transistor overheats and the drive detects an rr [Dynamic Braking
Transistor Fault] fault.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the braking resistor overheats and the drive detects an rH [Braking Resistor Overheat]
fault.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects a cooling fan failure in the drive.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when drive receives a Run command and the drive detects the motor magnetic pole position
of the PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the bit specified by H2-07 turns on regarding the MEMOBUS register address
configured with H2-08.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the bit specified by H2-10 turns on regarding the MEMOBUS register address
configured with H2-09.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activated after the drive stops operating and after the time set with b8-51 [Standby Mode Wait Time].
ON : The Run command turns off and the drive stops operating. When time set in b8-51 [Standby Mode Wait Time] is
expired, the magnetic contactor on the input side turns off.
OFF : The Run command turns on and the magnetic contactor on the input side turns on.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the monitor value set with H2-20 is within range of H2-21 and H2-22 for the time set in
H2-24.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the when the monitor value set with H2-26 is outside the range of H2-27 and H2-28 for
the time set in H2-30.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when there is an external 24V power supply between terminals PS-AC.
ON : The external 24V power supply is not supplying power.
OFF : The external 24V power supply is supplying power.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects a LoG [Com Error / Abnormal SD card].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DriveWorksEZ digital output 1. Refer to the DriveWorksEZ online manual for more information.
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.10 H: Terminal Functions
Ref.
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
11
605