YASKAWA GA800 Technical Reference page 605

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

Setting Value
Function
139
!Watt Hour Pulse Output
13C
!LOCAL Control
Selected
13D
!During Speed Search
13E
!PID Feedback Low
13F
!PID Feedback High
14A
!During KEB Ride-Thru
14B
!During Short Circuit
Braking
14C
!During Fast Stop
14D
!oH Pre-Alarm Reduction
Limit
14E
!Braking Transistor Fault
(rr)
14F
!Braking Resistor
Overheat (rH)
160
!Internal Cooling Fan
Failure
161
!RotorPositionDetection
Complete
162
!Modbus Reg 1 Status
Satisfied
163
!Modbus Reg 2 Status
Satisfied
165
!Standby Output
166
!Comparator 1
167
!Comparator 2
169
!External Power 24V
Supply
16A
!Data Logger Error
190
!DWEZ Digital Output 1
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
V/f
CL-V/f
OLV
CLV
AOLV
Outputs the pulse that shows the watt hours.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the Run command source or frequency reference source is LOCAL.
ON : REMOTE
OFF : LOCAL
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive does speed search.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects FbL [PID Feedback Loss].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects FbH [Excessive PID Feedback].
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive executes the KEB Ride-Thru function.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates during Short Circuit Braking.
Note:
When A1-02 = 8 [Control Method Selection = EZ Vector Control], this function is available when you use a PM
motor.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the fast stop is in operation.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when L8-03 = 4 [Overheat Pre-Alarm Selection = Operate at Reduced Speed (L8-19)] and
oH [Heatsink Overheat] does not clear after the drive decreases the frequency for 10 cycles.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the internal braking transistor overheats and the drive detects an rr [Dynamic Braking
Transistor Fault] fault.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the braking resistor overheats and the drive detects an rH [Braking Resistor Overheat]
fault.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects a cooling fan failure in the drive.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when drive receives a Run command and the drive detects the motor magnetic pole position
of the PM motor.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the bit specified by H2-07 turns on regarding the MEMOBUS register address
configured with H2-08.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the bit specified by H2-10 turns on regarding the MEMOBUS register address
configured with H2-09.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal activated after the drive stops operating and after the time set with b8-51 [Standby Mode Wait Time].
ON : The Run command turns off and the drive stops operating. When time set in b8-51 [Standby Mode Wait Time] is
expired, the magnetic contactor on the input side turns off.
OFF : The Run command turns on and the magnetic contactor on the input side turns on.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the monitor value set with H2-20 is within range of H2-21 and H2-22 for the time set in
H2-24.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the when the monitor value set with H2-26 is outside the range of H2-27 and H2-28 for
the time set in H2-30.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when there is an external 24V power supply between terminals PS-AC.
ON : The external 24V power supply is not supplying power.
OFF : The external 24V power supply is supplying power.
V/f
CL-V/f
OLV
CLV
AOLV
The terminal deactivates when the drive detects a LoG [Com Error / Abnormal SD card].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the DriveWorksEZ digital output 1. Refer to the DriveWorksEZ online manual for more information.
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.10 H: Terminal Functions
Ref.
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
929
11
605

Advertisement

Table of Contents
loading

Table of Contents