N8: Pm Motor Control Tuning - YASKAWA GA800 Technical Reference

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

No.
Name
(Hex.)
n7-11
Drv Mode Switch
Hysteresis Band
(311B)
Expert
n7-13
Driving Method
Switching Time
(311D)
Expert
n7-17
Resistance
TemperatureCorrection
(3122)

n8: PM Motor Control Tuning

No.
Name
(Hex.)
n8-01
Pole Position Detection
Current
(0540)
n8-02
Pole Alignment Current
Level
(0541)
Expert
n8-03
Pole Position Detection
Time
(0542)
n8-04
Pole Alignment Time
(0543)
Expert
n8-11
Observer Calculation
Gain 2
(054A)
n8-14
Polarity Compensation
Gain 3
(054D)
Expert
n8-15
Polarity Compensation
Gain 4
(054E)
Expert
n8-21
Motor Back-EMF (Ke)
Gain
(0554)
Expert
n8-23
ACR q Gain @PoleEst
(0556)
Expert
n8-24
ACR q Integral Time
@PoleEst
(0557)
Expert
n8-25
ACR q Limit @PoleEst
(0558)
Expert
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Description
V/f
CL-V/f
OLV
CLV
AOLV
Usually it is not necessary to change this setting. Sets the hysteresis level for Switching
Speed set in n7-10 [Pull-in Current Switching Speed].
When the speed is lower than n7-10 + n7-11 during acceleration, the drive enables pull-in
current.
Note:
• When the drive accelerates, it enables these settings:
–Motor speed ≤ n7-10 + n7-11: n8-51 [Pull-in Current @ Acceleration]
–Motor speed > n7-10 + n7-11: b8-01 [Energy Saving Control Selection]
• If there is a large quantity of oscillation when you operate in the low speed range,
increase the setting value.
• When it is most important to save energy in the low speed range, decrease the setting
value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a time to enable the pull-in current commands.
If there is a large quantity of oscillation at speeds around n7-10 [Pull-in Current Switching
Speed], decrease the setting in 20 ms decrements.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to adjust for changes in the motor resistance value caused by changes in
the temperature.
0 : Invalid
1 : Valid (Only 1 time)
2 : Valid (Every time)
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Initial Rotor Position Estimated Current as a percentage where E5-03 [PM Motor
Rated Current (FLA)] = 100%. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the current at the time of polar attraction as a percentage where E5-03 [PM Motor
Rated Current (FLA)] = 100%. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of the Current Starting Time, which is used for Z Pulse Offset Tuning.
Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of the Polar Attraction Time, which is used for Z Pulse Offset Tuning.
Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for speed estimation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the proportional gain for current regulator q-axis control when the drive estimates the
initial pole. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the integral time for current regulator q-axis control when the drive estimates the
initial pole. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the q-axis limit of the current regulator when the drive estimates the initial pole.
Usually it is not necessary to change this setting.
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
11.12 n: Special Adjustment
Default
Ref.
(Range)
5.0%
1023
(1.0 - 20.0%)
100 ms
1023
(0 - 1000 ms)
1
1023
(0 to 2)
Default
Ref.
(Range)
50%
1024
(0 - 100%)
80%
1024
(0 - 150%)
1.5 s
1024
(1.5 - 5.0 s)
1.5 s
1024
(1.5 - 5.0 s)
Determined by n8-72
1025
(0.0 - 1000.0)
1.000
1025
(0.000 - 10.000)
0.500
1025
(0.000 - 10.000)
0.90
1025
(0.80 - 1.00)
0
1025
(0 - 2000)
0.0 ms
1025
(0.0 - 100.0 ms)
0%
1025
(0 - 150%)
11
629

Advertisement