5.2 European Standards
A - Grounding surface (Remove any paint or sealant.)
B - Enclosure panel
C - Metal plate
D - Drive
E - Ground the shield.
5.
Connect the DC link choke to decrease harmonic distortion. Refer to
DC link choke.
Note:
• To maintain compliance with IEC/EN 61000-3-2 on drive models 2004, 2006, 4002, and 4004, install a DC link choke.
• The terminal block for the drive main circuit and the terminal block for the DC link choke have different shapes. The drive has a
European-style terminal block, and the DC link choke has a round terminal block. Correctly prepare the ends of the wiring.
• Ground the DC link choke (option) on the back of the mounting base. Remove all paint from the mounting surface of the control
panel.
268
Figure 5.19 EMC Noise Filter and Drive Installation Procedure
F - Motor
G - Motor cable (Braided shield cable: 10 m (32.8 ft)
maximum)
H - Cable clamp
I - Grounding wire
J - EMC noise filter
DC Link Chokes on page 270