YASKAWA GA800 Technical Reference page 685

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

*1
No.
Name
Unit
-
Drive Model
Normal /
C6-01
Heavy Duty
Selection
Drive Model
o2-04
(KVA)
Hex.
Selection
E2-11
HP
Motor Rated
(E4-11, E5-
Power
(kW)
02)
E2-02
Motor Rated
Hz
Slip
(E4-02)
E2-03
Motor No-
A
Load Current
(E4-03)
Motor Line-to-
E2-05
Line
Ω
(E4-05)
Resistance
Motor
E2-06
Leakage
%
(E4-06)
Inductance
E2-10
Motor Iron
W
Loss
(E4-10)
PM Motor
E5-01
Code Selection
Power Loss
L2-02
Ride Through
Time
Minimum
L2-03
Baseblock
Time
Powerloss V/f
L2-04
Recovery
Ramp Time
Undervoltage
L2-05
Detection Lvl
(Uv1)
Motor Accel
L3-24
Time @ Rated
Torque
Overheat
L8-02
°C
Alarm Level
Output Ground
L8-09
Fault
Detection
Carrier
L8-38
Frequency
Reduction
Hunting
n1-01
Prevention
Selection
Hunting
n1-03
Prevention
ms
Time Constant
Hunting
n1-16
Prevention
High Fc Gain
Motor Inertia
n5-02
Acceleration
Time
*1
Parameters within parentheses are for motor 2.
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
-
4075
HD
ND
-
0
1
00A1
40
50
(30)
(37)
1.8
1.33
10.9
19.1
0.269
0.155
20.7
18.8
750
925
-
1242
1242
s
2
2
s
1.1
1.1
s
0.6
0.6
-
380
380
s
0.323
0.32
120
120
-
1
1
-
2
2
-
2
2
10
10
-
0.50
0.50
s
0.323
0.32
11.21 Defaults by Drive Model and Duty Rating ND/HD
Default
4089
HD
ND
HD
0
1
0
00A2
50
60
60
(37)
(45)
(45)
1.33
1.6
1.6
19.1
22
22
0.155
0.122
0.122
18.8
19.9
19.9
925
1125
1125
1243
1243
1244
2
2
2
1.1
1.2
1.2
0.6
0.6
0.6
380
380
380
0.32
0.387
0.387
115
115
126
1
1
1
2
2
2
2
2
2
10
10
10
0.50
0.50
0.50
0.32
0.387
0.387
4103
4140
ND
HD
1
0
00A3
00A4
75
75
(55)
(55)
1.46
1.46
24
24
0.088
0.088
20
20
1260
1260
1244
1245
2
2
1.2
1.2
1
1
380
380
0.317
0.317
120
120
1
1
2
2
2
2
10
30
0.50
0.50
0.317
0.317
ND
1
100
(75)
1.39
36
0.092
20
1600
1245
2
1.3
1
380
0.533
120
1
2
2
30
0.50
0.533
11
685

Advertisement

Table of Contents
loading

Table of Contents