YASKAWA GA800 Technical Reference page 552

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

11.5 b: Application
No.
Name
(Hex.)
b8-04
Energy Saving
Coefficient Value
(01CF)
Expert
b8-05
Power Detection Filter
Time
(01D0)
Expert
b8-06
Search Operation Voltage
Limit
(01D1)
Expert
b8-16
PM E-Save Coefficient
Ki
(01F8)
Expert
b8-17
PM E-Save Coefficient
Kt
(01F9)
Expert
b8-18
E-Save d-axis Current
FilterTime
(01FA)
Expert
b8-19
E-Save Search Frequency
(0B40)
Expert
b8-20
E-Save Search Width
(0B41)
Expert
b8-21
PM E-Save Search Gain
(0B42)
Expert
b8-22
PM E-Save Search LPF
Cutoff Freq
(0B43)
Expert
b8-23
PM E-Save Search Limit
(0B44)
Expert
b8-24
PM E-Save High Freq
ACR Gain
(0B45)
Expert
b8-25
PM E-Save Search Start
Level
(0B46)
Expert
b8-26
PM E-Save Power
Setpoint
(0B47)
Expert
b8-28
Over Excitation Action
Selection
(0B8B)
Expert
b8-29
Energy Saving Priority
Selection
(0B8C)
b8-50
Standby Mode Selection
(0B0D)
b8-51
Standby Mode Wait Time
(0B01)
552
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Energy-saving control coefficient to maintain maximum motor efficiency. The
default setting is for Yaskawa motors.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant to measure output power.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the voltage limit for Search Operation as a percentage of the motor rated voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Sets torque linearity. This parameter uses the Ki value from the motor nameplate. Usually
it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets torque linearity. This parameter uses the Kt value from the motor nameplate. Usually
it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the d-axis current reference filter time constant.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency of Energy-saving control search operations. Usually it is not necessary
to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the amplitude of Energy-saving control search operations.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain of Energy-saving control search operations.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency of the filter used to extract the high-efficiency phase from search
operations. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the search operations output limit. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for high-frequency current control.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the start level for search operations.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a value to increase torque accuracy.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for excitation operation.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the priority of drive response between changes to the load or Energy-saving control.
Enable this to prioritize energy-saving control. Disable this to prioritize tracking related to
fast load changes, and prevent motor stall.
0 : Priority: Drive Response
1 : Priority: Energy Savings
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Standby Mode function.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time before turning off the electromagnetic contactor after the drive stops.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Default
Ref.
(Range)
Determined by C6-01,
763
E2-11, and o2-04
(0.00 - 655.00)
20 ms
764
(0 - 2000 ms)
0%
764
(0 - 100%)
1.00
764
(0.00 - 3.00)
1.00
764
(0.00 - 3.00)
0.100 s
764
(0.000 - 5.000 s)
Determined by A1-02
765
(10 - 300 Hz)
1.0 degrees
765
(0.1 - 5.0 degrees)
0.3Hz
765
(0.1 - 20.0 Hz)
10.0 Hz
765
(1.0 - 30.0 Hz)
15.0 degrees
765
(0.0 - 30.0 degrees)
200.0 Hz
766
(100.0 - 1000.0 Hz)
10.0%
766
(0.0 - 100.0%)
0.0%
766
(-10.0 - +10.0%)
0
766
(0, 1)
0
766
(0, 1)
0
766
(0, 1)
600 s
767
(0 - 6000 s)

Advertisement

Table of Contents
loading

Table of Contents