F6-58: DeviceNet Torque Scaling
No.
Name
(Hex.)
F6-58
DeviceNet Torque Scaling
(03D9)
F6-59: DeviceNet Power Scaling
No.
Name
(Hex.)
F6-59
DeviceNet Power Scaling
(03DA)
F6-60: DeviceNet Voltage Scaling
No.
Name
(Hex.)
F6-60
DeviceNet Voltage Scaling
(03DB)
F6-61: DeviceNet Time Scaling
No.
Name
(Hex.)
F6-61
DeviceNet Time Scaling
(03DC)
F6-62: DeviceNet Heartbeat Interval
No.
Name
(Hex.)
F6-62
DeviceNet Heartbeat
Interval
(03DD)
F6-63: DeviceNet Network MAC ID
No.
Name
(Hex.)
F6-63
DeviceNet Network MAC
ID
(03DE)
F6-64 to F6-67: Dynamic Out Assembly 109 Param1 to 4
No.
Name
(Hex.)
F6-64 to F6-67
Dynamic Out Assembly 109
Param 1 to 4
(03DF - 03E2)
F6-68 to F6-71: Dynamic In Assembly 159 Param 1 to 4
No.
Name
(Hex.)
F6-68 to F6-71
Dynamic In Assembly 159
Param 1 to 4
(03E3, 03E4,
03C7, and 03C8)
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque scale of the DeviceNet communication master.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the power scale of the DeviceNet communication master.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the voltage scale of the DeviceNet communication master.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time scale of the DeviceNet communication master.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the heartbeat for DeviceNet communication. Set this parameter to 0 to disable the heartbeat
function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to see the actual DeviceNet MAC address using the keypad. This parameter
functions as a monitor only.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Configurable Outputs 1 to 4 written to the MEMOBUS register.
V/f
CL-V/f
OLV
CLV
AOLV
Sets Configurable Inputs 1 to 4 read from the MEMOBUS register.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
12.7 F: Options
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(-15 - +15)
Default
(Range)
0
(0 - 10)
Default
(Range)
63
(0 - 63)
Default
(Range)
0000H
(0000H - FFFFH)
Default
(Range)
0000H
(0000H - FFFFH)