n4-68: Speed Estimation Filter Time
No.
Name
(Hex.)
n4-68
Speed Estimation Filter
Time
(1B88)
If the motor speed oscillates in the high speed range, set the value to 0.010 s.
n4-69: Flux Control Response
No.
Name
(Hex.)
n4-69
Flux Control Response
(1B89)
If step-out occurs when the load changes, decrease the setting value in 1.00 increments.
Note:
If heavy loads decrease motor speed, increase the setting value in 1.00 increments. If it does not get better, increase n4-74 [Limit of Flux
Loop] in 20% increments.
n4-70: Speed Command Comp @ Low Freq
No.
Name
(Hex.)
n4-70
Speed Command Comp @
Low Freq
(1B8A)
This function makes the control more stable when you operate at low speeds.
• If the load is light when the drive operates in the low speed range, increase the setting value in 0.3 Hz increments.
Note:
Increase the setting value to increase the stability when the drive is operating at low speed. It can make the speed control less accurate.
• When the motor rotates faster than the frequency reference at low speed, decrease the setting value in 0.1 Hz
increments.
Note:
If you set the value too low, the motor can rotate in reverse.
n4-71: Flux Estimation Method
No.
Name
(Hex.)
n4-71
Flux Estimation Method
(1B8B)
Expert
0 : Method 1
1 : Method 2
n4-72: Speed Feedback Mode
No.
Name
(Hex.)
n4-72
Speed Feedback Mode
(1B8C)
You can connect a PG-B3 or PG-X3 encoder option in AOLV control. You can use the encoder option for better speed
control precision.
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
V/f
CL-V/f
OLV
CLV
AOLV
Sets the primary delay time constant for the speed estimation value. Usually it is not necessary to
change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Unifies control of magnetic flux to make motor vibrations more stable.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to make the drive more stable when operating at low speeds. Usually it is not
necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the flux estimation method. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the requirement for an encoder option when A1-02 = 4 [Control Method Selection = Advanced
Open Loop Vector].
12.10 n: Special Adjustment
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
0.001 s
(0.001 - 0.010 s)
Default
(Range)
1.00
(0.00 - 60.00)
Default
(Range)
1.00 Hz
(0.00 - 6.00 Hz)
Default
(Range)
0
(0, 1)
Default
(Range)
0
(0, 1)
12