YASKAWA GA800 Technical Reference page 702

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

12.2 A: Initialization Parameters
No.
Name
(Hex.)
A1-06
Application Preset
(0127)
The drive software contains the application presets shown below. Set A1-06 to align with the application to let the
drive automatically set the best parameter settings for the selected application. The drive saves parameters frequently
used for the application in parameters A2-01 to A2-16 [User Parameters 1 to 16] for easy configuration and reference
in [User Custom Parameters] in the main menu.
• Water supply pump
• Conveyor
• Exhaust fan
• HVAC fan
• Air compressor
Note:
• Before you set A1-06, make sure that you set A1-03 = 2220, 3330 [Initialize Parameters = 2-Wire Initialization, 3-Wire Initialization] to
initialize parameters.
• It is not possible to change the A1-06 value. To set an application preset, first set A1-03 = 2220 to initialize parameters, then set this
parameter. If initializing all parameters will cause a problem, do not change the settings.
If you set A2-33 = 1 [User Parameter Auto Selection = Enabled: Auto Save Recent Parms] to set parameters to A2-17 to A2-32 [User
Parameters 17 to 32] automatically, the drive will reset these parameters when you change the A1-06 setting.
0 : General-purpose
The drive saves the parameters in
Table 12.3 Parameters Saved as User Parameters with the General-purpose Preset
User Parameter No.
A2-01
A2-02
A2-03
A2-04
A2-05
A2-06
A2-07
A2-08
A2-09
A2-10
A2-11
A2-12
A2-13
A2-14
A2-15
A2-16
A2-17
A2-18
A2-19
A2-20
A2-21
A2-22
A2-23
702
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive to operate in selected application conditions.
Table 12.3
as user parameters.
Parameter No. Saved
A1-02
b1-01
b1-02
b1-03
C1-01
C1-02
C6-01
C6-02
d1-01
d1-02
d1-03
d1-04
d1-17
E1-01
E1-03
E1-04
E1-05
E1-06
E1-09
E1-13
E2-01
E2-04
E2-11
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Default
(Range)
0
(0 - 5)
Name
Control Method Selection
Frequency Reference Selection 1
Run Command Selection 1
Stopping Method Selection
Acceleration Time 1
Deceleration Time 1
Normal / Heavy Duty Selection
Carrier Frequency Selection
Reference 1
Reference 2
Reference 3
Reference 4
Jog Reference
Input AC Supply Voltage
V/f Pattern Selection
Maximum Output Frequency
Maximum Output Voltage
Base Frequency
Minimum Output Frequency
Base Voltage
Motor Rated Current (FLA)
Motor Pole Count
Motor Rated Power

Advertisement

Table of Contents
loading

Table of Contents