YASKAWA GA800 Technical Reference page 267

Ac drive for industrial applications
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

Note:
• Use a braided shield cable for the drive and motor wiring or put the wires through a metal conduit.
• The maximum wiring length between the drive and motor is 10 m (32.8 ft). Keep the wire as short as possible.
• Keep the grounding wire as short as possible.
4.
Use a cable clamp to ground the motor cable to the metal plate.
Note:
Make sure that the protective ground wire complies with technical specifications and local safety standards.
A - Braided shield cable
B - Metal plate
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
C - Cable clamp (conductive)
Figure 5.18 Ground the Shield
5.2 European Standards
267
5

Advertisement

Table of Contents
loading

Table of Contents